Data Sheet

BMS10x0
26 www.roboteq.com Version 1.0 March 2, 2018
Command Arguments Description Examples
CCHT Chemistry Option Cell Chemistry Type ^CCHT 1
0: LiPo
1: LiFePO4
2: Custom
BPRC Value mV Balance Precision ^BPRC 10
ISRG Aux Output Option Aux Output Function ^ISRG 0
0: Disable
1: Brake Resistor
2: Fan
3: Heater
CRES Value in uOhm Cell Internal Resistance ^CRES 1
(0.001 mOhm)
STYP Sensor Index, Type Select Temperature Sensor Type ^STYP 2 1
0: Disable
1: 10k NTC
MXRTR Channel, Number Rtr Max Retry Times ^MXRTR 2 0
REDL Channel, Time ms Delay Between Retries ^REDL 2 1000
MINOP Sensor Idx, Celsius Minimum Operating Temperature ^MINOP 2 -10
DMOD Modbus Mode Set Modbus Mode ^DMOD 4
0: Off
3: RS232 ASCII
4: RS485 ASCII
MNOD Node ID Set Modbus Node ID ^MNOD 1
Maintenance Commands
Maintenance commands are used for performing maintenance functions on RoboteQ’s
BMS10x0. The commands seen in Table 16, below, can be used by typing the “%”
character before the command name.
TABLE 16.
Command Arguments Description Examples
RESET Key Reset Controller %RESET 321654987
SLD Key Load Microbasic scripts %SLD 321654987
EERST Key Restore Factory Defaults %EERST 321654987
EESAV Save Parameters to EEPROM %EESAV
EELD Load Parameters from EEPROM %EELD
CLSAV Key Calibrations Values to EEPROM %CLSAV 321654987
CLRST Key Load Factory Default Configurations %CLRST 321654987
LK Lock Configuration Access %LK
UK Unlock Configuration Access %UK
STIME Hours Mins Secs Set Time
DFU Key Enter Firmware Update via USB %DFU 321654987
BTCMD BT Command String Send BT Configuration Commands %BTCMD “AT”
Response “OK”