Data Sheet

HDC24xx Motor Controller Datasheet 9
Status LED Flashing Patterns
Status LED Flashing Patterns
After the controller is powered on, the Power LED will tun on, indicating that the controller is On. The Status LED
will be flashing at a 2 seconds interval. The flashing pattern provides operating or exception status information.
Additional status information may be obtained by monitoring the controller with the PC utility.
Electrical Specifications
Absolute Maximum Values
The values in the table below should never be exceeded, Permanent damage to the controller may result.
TABLE 6.
Parameter Measure point Models Min Typ Max Units
Battery Leads Voltage Ground to VMot HDC2450(S) 50 Volts
HDC2460 60 Volts
HDC2472(S) 36 75 Volts
Reverse Voltage on Battery
Leads
Ground to VMot All -1 Volts
Power Control Voltage Ground to Pwr Control wire All 65 Volts
Motor Leads Voltage Ground to M1+, M1-, M2+, M2- HDC2450(S) 50 (1) Volts
HDC2460 60 (1) Volts
HDC2472(S) 36 75 (1) Volts
Digital Output Voltage Ground to Output pins All 30 Volts
Analog and Digital Inputs
Volt age
Ground to any signal pin on 25 & 9-pin
connectors
All 15 Volts
RS232 I/O pins Voltage External voltage applied to Rx/Tx pins All 15 Volts
Case Temperature Case All -40 85 oC
Humidity Case All 100 (2) %
FIGURE 8. Normal Operation Flashing Patterns
Under or Over Voltage
Power Stage Off
Short Detected
Overheat
FIGURE 9. Exception or Fault Flashing Patterns