Data Sheet

14 FBL2360 Brushless DC Motor Controller Datasheet Version 1.1, May 24, 2018
Power Stage Electrical Specifications (at 25ºC ambient)
TABLE 8.
Continuous Max
Current per channel Measure point Model Min Ty p Max Units
Battery Leads Voltage Ground to VBat All 0 (1) 63 Volts
Motor Leads Voltage Ground to U, V, W
wires
All 0 (1) 63 (2) Volts
Power Control Voltage Ground to Power
Control wire
All 0 (1) 65 Volts
Minimum Operating Voltage VBat or Pwr Ctrl wires All 9 (3) Volts
Over Voltage protection range Ground to VBat All 5 60 (4) 63 Volts
Under Voltage protection range Ground to VBat All 0 5 (4) 63 Volts
Idle Current Consumption VBat or Pwr Ctrl wires All 50 100 (5) 150 mA
ON Resistance (Excluding
wire resistance)
VBat to U, V or W.
Ground to U, V or W
FBL2360 2.5 mOhm
FBL2360S 1.25 mOhm
Max Current for 30s Motor current FBL2360 60 Amps
FBL2360S 120 Amps
Continuous Max Current per
channel
Motor current FBL2360 40 (6) Amps
FBL2360S 80 (6) Amps
Current Limit range Motor current FBL2360 10 50 (7) 60 Amps
FBL2360S 20 100 (7) 120 Amps
Stall Detection Amps range Motor current FBL2360 10 60 (7)
60
Amps
FBL2360S 20 120 (7)
120
Amps
Stall Detection timeout range Motor current All 1 500 (8)
65000
milli-
sec-
onds
Short Circuit Detection
threshold (9)
Between Motor
wires or Between
Motor wires and
round
FBL2360
500 (10)
Amps
FBL2360S
1000
(10)
Amps
Short Circuit Detection
threshold
Between Motor
wires and VBat
All No Protection. Permanent damage
will result
Motor Acceleration/
Deceleration range
Motor Output
All 100 500
(11)
65000 milli-
sec-
onds
Note 1: Negative voltage will cause a large surge current. Protection fuse needed if battery polarity inver-
sion is possible
Note 2: Maximum regeneration voltage in normal operation. Never inject a DC voltage from a battery or
other fixed source
Note 3: Minimum voltage must be present on VBat or Power Control wire
Note 4: Factory default value. Adjustable in 0.1V increments
Note 5: Current consumption is lower when higher voltage is applied to the controller’s VBat or PwrCtrl
wires