User's Manual
AX3500 Motor Controller User’s Manual 109
Fault Messages
Fault Messages
The AX3500 uses the LED display to report fault conditions. When these messages are 
displayed, the motors are normally stopped.
No Control
This message is displayed in the R/C mode to indicate that no valid radio signal has been 
detected at its inputs or that radio signal has been lost. When the controller is configured 
in the mixed mode, signals on channel 1 and channel 2 must be present to enable the con-
troller. When the controller is configured in the separate mode, a signal received on either 
channel will enable the controller. When enabled, the controller will display the normal 
motor status described previously.
The “no control” message is displayed using the following sequence of digits.
Forward Reversed
Reversed Reversed
MOSFET Transistors are 
OFF
Motors are freewheeling
Signals a temporary Off condition in 
case of Overvoltage, undervoltage or 
Overtemperature condition (see 
page 38), of if Dead-man switch is 
activated (see page 52)
Rapidly Flashing
MOSFET Transistors are 
OFF
Motors are freewheeling
Controller is permanently Off after an 
Encoder Error, Short Circuit detection 
or Emergency Stop activation. Con-
troller must be restarted.
TABLE 18. Motor Commands and resulting display
Possible Display Motor 1 Motor 2 Comment