Datasheet
8 SDC21xx Motor Controller Datasheet Version 1.3. April 05, 2014
Status LED Flashing Patterns
After the controller is powered on, the Power LED will tun on, indicating that the controller is On. The Status LED
will be flashing at a 2 seconds interval. The flashing pattern provides operating or exception status information.
Additional status information may be obtained by monitoring the controller with the PC utility.
Self-Test and Reset Default Configuration
It is possible to verify that the controller is functioning by activating a self-test that will in turn ramp the motor(s)
up to full forward power and down to full reverse power. Then it toggles each digital output. To activate self-test,
turn off the controller, short RS232 Rx and Tx pins together (Pins 2 and 3 of I/O connector), and turn the controller
on again. The process will repeat until power is turned off and the RS232 is no longer shorted. Activating the self-
test also resets the controller settings to factory defaults.
Note: RS232 cannot be connected to PC as this will prevent the controller from entering the self-test mode.
Electrical Specifications
Absolute Maximum Values
The values in the table below should never be exceeded. Permanent damage to the controller may result.
TABLE 5.
Parameter Measure point Models Min Typ Max Units
Battery Leads Voltage Ground to VMot SDC2130 10 40 Volts
SDC2160 10 62 Volts
Reverse Voltage on Bat-
tery Leads
Ground to VMot All -1 Volts
Motor Leads Voltage Ground to M1+, M1-,
M2+, M2-
SDC2130 35 Volts
SDC2160 62 Volts
Digital Output Voltage Ground to Output pins All 40 Volts
RS232/USB Mode
Idle - Waiting for Command
RC Pulse Mode
Analog Mode
FIGURE 14. Normal Operation Flashing Patterns
Under or Over Voltage
Power Stage Off
Short Detected
Overheat
FIGURE 15. Exception or Fault Flashing Patterns