User Guide
Table Of Contents
- 1 Safety Notices
- 2 Introduction
- 3 Product Specifications
- 4 Connections
- 5 Communications Protocols
- 6 GPS Synchronization
- 7 Key characteristics
- 8 Point Cloud
- 9 Laser Channels and Vertical Angles
- 10 Calibrated Reflectivity
- 11 Troubleshooting
- Appendix A ▪ Point Time Calculate
- Appendix B ▪ Information Registers
- B.1 Motor(MOT_SPD)
- B.2 Ethernet(ETH)
- B.3 FOV Setting (FOV SET)
- B.4 Motor Phase Offset (MOT_PHASE)
- B.5 Top Board Firmware (TOP_FRM)
- B.6 Bottom Board Firmware (BOT_FRM)
- B.7 Serial Number(SN)
- B.8 Software Version(SOFTWARE_VER)
- B.9 UTC Time(UTC_TIME)
- B.10 STATUS
- B.11 Fault Diagnosis
- B.12 ASCII code in GPRMC Packet
- B.13 Corrected Vertical Angle (COR_VERT_ANG)
- B.14 Corrected Horizontal Offset Angle (COR_HOR_AN
- Appendix C ▪ RSView
- Appendix D ▪ RS-LiDAR-32 ROS Package
- Appendix E ▪ Dimensions
- Appendix G ▪ How to Distinguish the Port Number of

RS-LiDAR-32 User Manual
57
3. We can modify the parameters to the ones we want to have, then click Set LiDAR. We need
re-power and connect the RS-LiDAR-32 to make the modified parameters valid. After the device
connecting again, we can use RSView to see the RS-LiDAR Information again to check if the
modification take effect.
Figure C-15: Set LiDAR information.
Attention 1: Please do not power off the sensor when we are setting LiDAR information, it may cause
the sensor internal parameters broken.
Attention 2: if we modify the MSOP Port or DIFOP parameters above, we need setting the RSView
MSOP Port and DIFOP Port according to C.8 section to make RS-LiDAR-32 can be connected correctly.
C.8 RSView Data Port
In the RS-LiDAR-32 factory firmware, the default MSOP port is 6699, the default DIFOP port is 7788, if
we change the RS-LiDAR-32 ports number by modify the 2 parameters in C.7 section, we need
configure the RSView Data Port first or we will see nothing in the RSView. If we do not know the
RS-LiDAR-32 ports configuration, we can use Wireshark to capture the packets to check the Dst Port.
Click Tools > Data Port, enter the real MSOP port and DIFOP port of RS-LiDAR-32, then click Set Data
Port. After that we can see the cloud point data again in the RSView.