18
25
-
5.4 Safety Requirement/安全性能
Items
Conditions and others
Performances
Charge Over Voltage
Protection
/过压充电
The standard charged battery is continue to be
charged with maximum charging current to n*6V
or the highest possible voltage(Choose the best
one), and keep the voltage by CV charging, until
the protection circuit starts.
/将电池组按标准充电方式充满电后,继续
最大充电电流恒流充至n*6V或者电池组可
承受的最高电压值(两者取较高者)并保持
该电压进行恒压充电,充电至保护电路起动。
The battery should be no fire, no
explosion or no leakage.
/电池组应不起火,不爆炸,不漏液。
Charge Over Current
Protection
/过流充电
The standard discharged battery is to be charged
with 1.5 times charge protection current, until the
protection circuit starts.
/电池组按标准放电方式放完电后,然后以 1.5
倍的过流充电保护电流进行恒流充电,直至保
护电路起动。
The battery should be no fire, no
explosion or no leakage.
/电池组应不起火,不爆炸,不漏液。
Over Discharge
Protection
/欠压放电
The standard charged battery is to be discharged
with maximum continuous discharge current,
until the protection circuit starts. then keep for 10
minutes, recharging the battery with standard
charge method.
/将电池按标准充电方式充满电后,以其最大持
续放电电流放电至保护电路起动,然后静
10min,继续 SPEC 规定方法充满电。
The battery should be no fire, no
explosion or no leakage.
/电池组应不起火,不爆炸,不漏液。
Over Load
Protection
/过载
The standard charged battery is to be discharged
with 1.5 times discharge protection current, until
the protection circuit starts.
/将电池按标准充电方式充满电后,然后以 1.5
倍过流保护电流恒流放电至保护电路起动
The battery should be no fire, no
explosion or no leakage.
/电池组应不起火,不爆炸,不漏液。
External Short
Circuit
/外部短路
The test should be conducted under 25±5.
The standard charged battery is to be
short-circuited by connecting the positive and
negative terminals of the battery with copper
The battery should be no fire, no
explosion, no smoke or no leakage.
/电池应不起火不爆炸,不冒烟或漏