SDS

Fujian SCUD Power Technology Co., Ltd.
Version
V1.9
File Name
BRR-2P4S-5200FL 锂离子电池规格书
Security Level
Internal public
飞毛腿公司机密,未经许可不得扩散。 -
14
25
-
/一段充电过电流保护值
/放电解除
1
st
Charge over current detection delay time
/一段充电过电流保护延迟时
s
0.40
0.50
0.60
1
st
Discharge over current detection current 1
/一段放电过电流保护值 1
A
8.91
10
11.11
Charge release
/充电解除
1
st
Discharge over current detection delay time 1
/一段放电过电流保护延迟时 1
ms
7
10
13
1
st
Discharge over current detection current 2
/一段放电过电流保护值 2
A
17.82
20
22.22
Charge release
/充电解除
1
st
Discharge over current detection delay time 2
/一段放电过电流保护延迟时 2
ms
0.7
1
1.3
1
st
Short circuit protection current
/一段短路保护
A
35.64
40
44.44
1
st
Short circuit protection current delay time
/一段短路保护延迟时间
us
160
200
500
Charge over temperature protection
/充电高温保护
62
65
68
The whole machine is
grade one protection
(50℃), the battery as the
secondary protection
/
整机一级保护
50
℃)
电池作为二级保护
Charge over temperature protection release
/充电高温保护恢复值
52
55
58
Charge under temperature protection
/充电低温保护
-6
-3
0
The whole machine is
grade one protection
(0℃), the battery as the
secondary protection
/整机一级保护0℃),
电池作为二级保护
Charge under temperature protection release
/充电低温保护恢复值
-1
2
5
Discharge over temperature protection
/放电高温保护
62
65
68
The whole machine is
grade one protection
(60℃), the battery as the
secondary protection
/整机一级保护60℃)
电池作为二级保护
Discharge over temperature protection release
/放电高温保护恢复值
52
55
58
Discharge under temperature protection
-26
-23
-20
The whole machine is