SDS

------------------------------------------------------------------------------------------------------------------
ATL confidential
Page 4 of 20
alkaline materials.
7
Voltage measurement: multi-meter. Physically seal the current protection to avoid explosion of
instrument by mistake.
Training skills
1
Turn on or move fan to exhaust smoke
2
Put out the fire with water mist extinguisher after wearing waterproof appliance. Measure the voltage
with multi-meter after the battery is dried. After the test voltage is normal, wrap the insulation with
plastic wrap, and then transport it.
3
The leaked electrolyte is neutralized with lime or NaOH powder at a ratio of 8% by weight
4
Use multi-meter to test voltage, pay special attention not to use the wrong gear (to physically close the
current block), to prevent instrument explosion
δΈ¨ Fire extinguishing precautions and protective measures
1
Alarm immediately when battery smoke or combustion is detected
2
Wear protective equipment, including respirators and masks. If water is used, PPE should include
raincoats, rain boots, insulated gloves, etc.
3
Cut off the power supply
4
Using solid fire extinguishers, it is recommended to use fire extinguishers in the following order: water
or mist, sand, fire blanket, dry powder, carbon dioxide fire extinguishers;
5
Exhaust smoke through fans or air circulation.
6
Drying, neutralizing. Dry by fan, if water is used, neutralize with calcium hydroxide.
6 Accidental Release Measures
Figure1water based fire
extinguisher
(Could be used for 36KV electrical
Figure2waters prayers to fire
extinguisher (Wear PPE to avoid
electrical shock)
Issue Date: 2021-04-27
SAFETY DATA SHEET
Dongguan PowerAmp Technology Ltd.
Rechargeable Li-ion Battery pack: BPR-1P6S-3600A1 ,22.2V,3468mAh,76.98Wh