Product Manual

Chapter 3-4
Robomow RL555, RL855, RL2000
Testing Base Station and Perimeter Wire charging 3.4
position
In order to ease adjusting Base Station’s position, use just 2 stakes
for the initial setting. After this test is completed, you will drive all 5
stakes in place.
Remove the Manual Controller from its holder and grasp it with
both hands.
Use the Navigation Pad on Manual Controller to drive Robomow:
position it on inner lawn, facing the Perimeter Wire, at least 3 m
(10 feet) in front of Base Station,
Reinsert Manual Controller in its holder.
Adjust the controller and its coil until it is at level with top of Robomow.
Verify that the section of the Perimeter Wire leading to the Base Station
is pegged and secured to the ground. Correct pegging if necessary.
Verify that ‘ON’ led on the Base Stat on is blinking
Press the
upper scroll arrow
on the Manual Controller once for
the message ‘Go to base’ and
then press

Robomow starts moving towards
Base Station.
Follow it and check if it docks properly into the Base Station: check that
the two metal contacts on Robomow’s front make full contact with the
metal plate under the Base Station’s cover.
If the plates are not in full contact ) , slightly move the
Base Station, for Robomow to get into the right position for
charging.
Once the test is completed, drive all 5 stakes into ground to fully secure
the Base Station.
Test the Perimeter Wire Position for Edge Mowing3.5
This test determines if there are minor adjustments needed in Perimeter
Wire positioning.
After the test is completed all pegs are driven in to secure the wire to
the ground.
Remove the Manual Control er from its holder and grasp it with
both hands.
Use the Navigat on Pad on Manual Controller to drive Robomow:
position it towards the Perimeter Wire.




) For RL2000: immediately after the Base
Station.




) For a non-base zone or RL555/RL855: Position
Robomow by any edge on the lawn.
Make sure the Perimeter Switch is turned on.
  
 
  
 

    
   

   









Min. 3 m(10 ft)
Position the
Robomow towards
the wire, after the
Base Station