• type: Boolean
• default: False
• description: Enables chunk data that is delivered with every image.
Custom GenICam features of the rc_visard
Category: ImageFormatControl
ExposureTimeAutoMax
• type: Float, ranges from 66 µs to 18000 µs
• default: 7000 µs
• description: Maximal exposure time in auto exposure mode (Auto, Section 6.1.3).
ExposureRegionOffsetX
• type: Integer in the range of 0 to 1280
• default: 0
• description: Horizontal offset of exposure region (Section 6.1.3) in pixel.
ExposureRegionOffsetY
• type: Integer in the range of 0 to 960
• default: 0
• description: Vertical offset of exposure region (Section 6.1.3) in pixel.
ExposureRegionWidth
• type: Integer in the range of 0 to 1280
• default: 0
• description: Width of exposure region (Section 6.1.3) in pixel.
ExposureRegionHeight
• type: Integer in the range of 0 to 960
• default: 0
• description: Height of exposure region (Section 6.1.3) in pixel.
Category: AcquisitionControl
AcquisitionAlternateFilter (read-only if IOControl component is not licensed)
• type: Enumeration, one of Off, OnlyHigh or OnlyLow
• default: Off
• description: If this parameter is set to OnlyHigh (or OnlyLow) and the LineSource is set to
ExposureAlternateActive for any output, then only camera images are delivered that are captured
while the output is high, i.e. a potentially connected projector is on (or low, i.e. a potentially connected
projector is off). This parameter is a simple means for only getting images without projected pattern.
The minimal time difference between camera and disparity images will be about 40 ms in this case
(see IOControl, Section 7.2.1).
AcquisitionMultiPartMode
• type: Enumeration, one of SingleComponent or SynchronizedComponents
• default: SingleComponent
8.1. GigE Vision 2.0/GenICam image interface 123