• Straight M12 plug to straight RJ45 connector, 10 m length: MURR Electronics Art.-Nr.: 7700-48521-
S4W1000
• Angled M12 plug to straight RJ45 connector, 10 m length: MURR Electronics Art.-Nr.: 7700-48551-
S4W1000
10.2.2 Power connections
An 8-pin A-coded M12 plug connector is provided for power and GPIO connectivity. Various cabling solutions
can be obtained from third party vendors. A selection of M12 to open ended cables is provided below. Cus-
tomers are required to provide power and GPIO connections to the cables according to the pinouts described in
Wiring (Section 3.5). The rc_visard’s housing must be connected to ground.
Sensor/Actor cable M12 socket to open end
• Straight M12 socket connector to open end, shielded, 10m length: Phoenix Contact SAC-8P-10,0-
PUR/M12FS SH, Art.Nr.: 1522891
• Angled M12 socket connector to open end, shielded 10m length: Phoenix Contact SAC-8P-10,0-
PUR/M12FR SH, Art.Nr.: 1522943
Sensor/Actor M12 socket for field termination
• Phoenix Contact SACC-M12FS-8CON-PG9-M, Art.Nr.:1513347
• TE Connectivity T4110011081-000 (metal housing)
• TE Connectivity T4110001081-000 (plastic housing)
10.2.3 Power supplies
The rc_visard is classified as an EN-55011 Class A industrial device. For connecting the sensor to residential grid
power, a power supply under EN 55011/55022 Class B has to be used.
It is the customer’s responsibility to obtain and install a suitable power supply satisfying EN 61000-6-2 for
permanent installation in industrial environments. One example that satisfies both EN 61000-6-2 and EN
55011/55022 Class B is the DIN-Rail mounted PULS MiniLine ML60.241 24V/DC 2.5 A by PULS GmbH
(http://www.pulspower.com). A certified electrician must perform installation.
Only one rc_visard shall be connected to a power supply at any time, and the total length of cables must be less
than 30 m.
10.3 Spare parts
No user-serviceable spare parts are currently available for rc_visard devices.
10.3. Spare parts 178