Technical Specs
4 Installation
Warning: The instructions on Safety (Section 2) related to the rc_visard must be read and understood prior
to installation.
4.1 Installation and configuration
The rc_visard offers a Gigabit Ethernet interface for connecting the device to a computer network. All communi-
cations to and from the device are performed via this interface. The rc_visard has an on-board computing resource
that requires booting time after powering up the device.
4.2 Power up
Note: Always fully connect and tighten the M12 power connector on the rc_visard before turning on the power
supply.
After connecting the rc_visard to the power, the LED on the front of the device should immediately illuminate.
During the device’s boot process, the LED will change color and will eventually turn green. This signals that all
processes are up and running.
If the network is not plugged in or the network is not properly configured, then the LED will flash red every 5
seconds. In this case, the device’s network configuration should be verified. See LED colors (Section 11.1) for
more information on the LED color codes.
4.3 Network configuration
The rc_visard requires an Internet Protocol (IP) address for communication with other network devices. The IP
address must be unique in the local network, and can be set automatically or manually.
Host name
MAC address
Fig. 4.3.1: Label on the rc_visard
19