Technical Specs

Warning: Exceeding maximum power rating values may lead to damage of the rc_visard, power supply, and
connected equipment.
Warning: A separate power supply must power each rc_visard.
Warning: Connection to domestic grid power is allowed through a power supply certified as EN55011 Class
B only.
3.5 Wiring
Cables are not provided with the rc_visard standard package. It is the customer’s responsibility to obtain the
proper cabling. Accessories (Section 10) provides an overview of suggested components.
Warning: Proper cable management is mandatory. Cabling must always be secured to the rc_visard mount
with a strain-relief clamp so that no forces due to cable movements are exerted on the rc_visards M12 connec-
tors. Enough slack needs to be provided to allow for full range of movement of the rc_visard without straining
the cable. The cable’s minimum bend radius needs to be observed.
The rc_visard provides an industrial 8-pin A-coded M12 socket connector for Ethernet connectivity and an 8-pin
A-coded M12 plug connector for power and GPIO connectivity. Both connectors are located at the back. Their
locations (distance from centerlines) are identical for the rc_visard 65 and rc_visard 160. The location of both
connectors on the rc_visard 65 is shown as an example in Fig. 3.5.1.
45.9
23.423.4
Ethernet
connector
Power
connector
Fig. 3.5.1: Locations of the electrical connections for the rc_visard 65, with Ethernet on top and power on the
bottom
Connectors are rotated so that standard 90° angled connectors will exit horizontally, away from the camera (away
from the cooling fins).
3.5. Wiring 14