Maintenance
Inspect the unit periodically for
leaks. The manufacturer does not
reimburse for lost refrigerant.
Adjust Tank Fill Level
Whenconnectedtoarefrigerantsource,theunit
maintainsadefaultvalueof15lbs.ofrefrigerant
intheinternalstoragevessel.Thisvaluemaybe
adjustedupordowntosuittheapplication.The
minimumvalueis4lbs.;themaximumvalueis
17lbs.
1.SelectSETUP MENU.ScrolltoADJUST
REFILL DEFAULT andselectSTART.
2.Theunitdisplays
15.00LBS.
ENTERTHEAMOUNTOFREFRIGERANTTHAT
THETANKFILLFUNCTIONSHOULDMAINTAIN
INTHEINTERNALSTORAGEVESSEL.
MAX=17.00LBMIN=04.00LB
SELECTSAVETOACCEPTOREXITTOABORT.
3.SelectSAVEtoacceptthedefaultamount,or
usethekeypadtoenteranamountandselect
SAVE.
Check for Leaks
Checktheunitforleakseverythreemonths,oras
speciedbylawinyourjurisdiction.
1.Turnoffthemainpowerswitch,anddisconnect
thepowercordfromtheoutlet.
2.
Openthereardoor.Removethetopcoverand
thefrontpanel.
3.
Usealeakdetectortoprobeallconnections
forrefrigerantleaks.Tightenttingsifaleakis
indicated.
4.Reassemblethebodypanels,andclosetherear
door.
Replace the Printer Paper
1.Presstheovalbuttonatthetopoftheprinterto
releasetheprintercover.SeeFigure16.
2.Graspthetabsandpullthecoverofftheprinter.
3.Removethepapercore.
4.Installthenewrollofpaperwiththeendofthe
paperatthetopoftheroll.
5.Assemblethecoverontotheprinterwiththeend
ofthepaperovertheroller.
Oval Button
Tab Tab
Paper Feed
Figure 16