User Manual

23
554228 Rev. E July 30, 2013
Maintenance
Change Vacuum Pump Oil
Formaximumvacuumpumpperformance,change
thevacuumpumpoilafterevery10hoursof
operation.
1.SelectSETUP MENU.ScrolltoMAINTAIN
VACUUM PUMPandselectSTART.
Thedisplayshowshowlongthevacuumpump
hasoperatedsincethelastoilchangeand
theamountoftimeremaininguntilthenextoil
changeisneeded:
VACUUMOILTIME:XX:XX
OILLIFEREMAINING:XX:XX
CHANGEVACUUMPUMPOILNOW?
SELECTYESTOCHANGEOILORNOTOEXIT
2.SelectYES.Thedisplayshows
WARMINGOILFORBETTERDRAIN.
VACUUMTIME:XX:XX
Allowthevacuumpumptorununtilit
automaticallystops.Thiswilltakeapproximately
oneminute.
3.Thedisplaythenshows
DRAINUSEDOILANDADD5OZOFNEWOIL.
PRESSNEXTTOCONTINUEOREXITTOABORT.
RefertoFigure15,andremovetheplugfrom
theoilllport.(Thepumpdrainsfasterwhen
vented.)
4.
Removetheoildrainttingcap,anddraintheoil
intoasuitablecontainerfordisposal.Replace
thecap.
5.
Attachtheexibletube/captotheoilbottle(from
theaccessorykit).Pouronly ve (5) ounces
ofvacuumpumpoilintothellport.Note: You
will top off the oil in the next step as the vacuum
pump is running.
6.SelectNEXT.Theunitdisplays
FILLVACUUMPUMPWITHNEWOILUNTIL
THELEVELREACHESTHEMIDDLEOFTHE
SIGHTGLASS.
REPLACECAPANDPRESSEXITWHEN
COMPLETE.
Whilethevacuumpumpisrunning,slowlyadd
oiluntilthelevelrisestothecenterofthesight
glass.
7.Installthepluginthellport,andselectEXIT.
Review the laws in your jurisdiction
to determine the correct disposal
procedure for pump oil. It is the
responsibility of the user to determine
if a material is a hazardous waste at
the time of disposal. Ensure you are
in compliance with all applicable laws
and regulations.
Oil Drain Fitting
Oil Fill
Port
Sight Glass
Figure 15
CAUTION: To prevent personal
injury, do NOT operate the unit at
any time without the oil ll port
plug installed, because the vacuum
pump is pressurized during normal
operation.