User Manual
23
554228 Rev. E July 30, 2013
Maintenance
Change Vacuum Pump Oil
Formaximumvacuumpumpperformance,change
thevacuumpumpoilafterevery10hoursof
operation.
1.SelectSETUP MENU.ScrolltoMAINTAIN
VACUUM PUMPandselectSTART.
Thedisplayshowshowlongthevacuumpump
hasoperatedsincethelastoilchangeand
theamountoftimeremaininguntilthenextoil
changeisneeded:
VACUUMOILTIME:XX:XX
OILLIFEREMAINING:XX:XX
CHANGEVACUUMPUMPOILNOW?
SELECTYESTOCHANGEOILORNOTOEXIT
2.SelectYES.Thedisplayshows
WARMINGOILFORBETTERDRAIN.
VACUUMTIME:XX:XX
Allowthevacuumpumptorununtilit
automaticallystops.Thiswilltakeapproximately
oneminute.
3.Thedisplaythenshows
DRAINUSEDOILANDADD5OZOFNEWOIL.
PRESSNEXTTOCONTINUEOREXITTOABORT.
RefertoFigure15,andremovetheplugfrom
theoilllport.(Thepumpdrainsfasterwhen
vented.)
4.
Removetheoildrainttingcap,anddraintheoil
intoasuitablecontainerfordisposal.Replace
thecap.
5.
Attachtheexibletube/captotheoilbottle(from
theaccessorykit).Pouronly ve (5) ounces
ofvacuumpumpoilintothellport.Note: You
will top off the oil in the next step as the vacuum
pump is running.
6.SelectNEXT.Theunitdisplays
FILLVACUUMPUMPWITHNEWOILUNTIL
THELEVELREACHESTHEMIDDLEOFTHE
SIGHTGLASS.
REPLACECAPANDPRESSEXITWHEN
COMPLETE.
Whilethevacuumpumpisrunning,slowlyadd
oiluntilthelevelrisestothecenterofthesight
glass.
7.Installthepluginthellport,andselectEXIT.
Review the laws in your jurisdiction
to determine the correct disposal
procedure for pump oil. It is the
responsibility of the user to determine
if a material is a hazardous waste at
the time of disposal. Ensure you are
in compliance with all applicable laws
and regulations.
Oil Drain Fitting
Oil Fill
Port
Sight Glass
Figure 15
CAUTION: To prevent personal
injury, do NOT operate the unit at
any time without the oil ll port
plug installed, because the vacuum
pump is pressurized during normal
operation.