User Manual

10
Operating Instructions
Recover Refrigerant from a Vehicle
1.Emptytheoildrainbottlebeforestartinga
recovery.Removetheoildrainbottlefromthe
machinebypullingthebottlestraightdownfrom
themagneticconnector—donotuseatwistingor
rockingmotion.SeeFigure6.
Note: The machine gives an alert when the oil drain
bottle needs to be emptied, but it is a good practice
to completely empty the oil drain bottle before
recovering an A/C system to prevent an inaccurate
oil charge later.
2.Connectthehigh-andlow-sidehosestothe
vehicleA/Csystem.
3.Openthecouplervalvesonthehosesbyturning
thecollarsclockwise.
4.SelectRECOVER.
5.Atthispoint,youhavetheoptiontostartthe
vehicle'sA/Ctoretrievepre-recoverydataand
selectRESETtosettheMinimum/Maximumdata
tocurrentlivepressurereadings.
6.SelectNEXTtobegintherecoveryprocess.
Note: The clicking noise indicates the solenoid is
opening and closing — this is normal.
7.Whenthesystemhasrecoveredto0psi,the
vacuumpumpstartsandrunsuntilrecoveryis
complete.Theunitthengoesintoanautomaticoil
drain—thismayrequire90secondstocomplete.
8.Aftertheoildrainiscomplete,thedisplayshows
RECOVEREDAMOUNTXX.XXLB.
RECOVERCOMPLETED.
OILDRAINEDXXXOZ.
PLEASEMAKEASELECTIONTOCONTINUE.
Atthispointyoumayprintoutrecovery
informationandpre-recoverdiagnosticsby
selectingPRINT.
Note: The displayed recovered weight can vary
depending on ambient conditions, and should not
be used as an indicator of scale accuracy.
9.Checktheoildrainbottle,andnotetheamountof
oilthatwasremovedfromtheA/Csystem.Thisis
theamountofnewoilthatmustbechargedinto
theA/Csystemafterevacuationiscomplete.
• Useonlynewoiltoreplacetheoilremovedduring
therecyclingprocess.
• Disposeofusedoilaccordingtolocal,state,and
federalregulations.
Recoveryiscomplete.Youarenowreadytoeither
advancetothechargeprocess,ortomakerepairsto
theA/Csystemfollowedbytheevacuationprocess.
Figure 6
Oil Drain
Bottle
Oil Inject
Bottle
Dye Inject
Bottle
Note: It is easier to remove the
oil drain bottle if the oil inject
bottle is removed rst.
Dye Inject
Oil Drain
Oil Inject
Operating Tips
After the RECOVER function is selected :
If system pressure is below 10 psi, until pressure
increases, the display reads
LOWRECOVERPRESSURE.
PLEASECHECKVALVESAND
CONNECTIONS.
SELECTYESTOCONTINUEWITH
RECOVERORSELECTVACUUM.
THEEXITKEYABORTSTHEFUNCTION.
Verify high- and low-side hoses are connected
and coupler valves are open. Select Yes to
recover, select Vacuum to bypass recover,
or select Exit.
If 100 lbs. (45 kg) or more of refrigerant has
been recovered since the last lter-drier
change, the display reads
FILTERWEIGHTXXXLB
To meet SAE J-2788 requirements, it is
mandatory to replace the lter-drier after
150 lbs. (68 kg) of refrigerant has been
ltered. The unit gives a warning to replace
the lter when lter weight reaches 100 lbs.;
when lter weight reaches 150 lbs., the unit
locks out and ceases to operate. Refer
to instructions outlined in the Maintenance
section under Replace the Filter-Drier.