User Manual
10
Operating Instructions
Recover Refrigerant from a Vehicle
1.Emptytheoildrainbottlebeforestartinga
recovery.Removetheoildrainbottlefromthe
machinebypullingthebottlestraightdownfrom
themagneticconnector—donotuseatwistingor
rockingmotion.SeeFigure6.
Note: The machine gives an alert when the oil drain
bottle needs to be emptied, but it is a good practice
to completely empty the oil drain bottle before
recovering an A/C system to prevent an inaccurate
oil charge later.
2.Connectthehigh-andlow-sidehosestothe
vehicleA/Csystem.
3.Openthecouplervalvesonthehosesbyturning
thecollarsclockwise.
4.SelectRECOVER.
5.Atthispoint,youhavetheoptiontostartthe
vehicle'sA/Ctoretrievepre-recoverydataand
selectRESETtosettheMinimum/Maximumdata
tocurrentlivepressurereadings.
6.SelectNEXTtobegintherecoveryprocess.
Note: The clicking noise indicates the solenoid is
opening and closing — this is normal.
7.Whenthesystemhasrecoveredto0psi,the
vacuumpumpstartsandrunsuntilrecoveryis
complete.Theunitthengoesintoanautomaticoil
drain—thismayrequire90secondstocomplete.
8.Aftertheoildrainiscomplete,thedisplayshows
RECOVEREDAMOUNTXX.XXLB.
RECOVERCOMPLETED.
OILDRAINEDXXXOZ.
PLEASEMAKEASELECTIONTOCONTINUE.
Atthispointyoumayprintoutrecovery
informationandpre-recoverdiagnosticsby
selectingPRINT.
Note: The displayed recovered weight can vary
depending on ambient conditions, and should not
be used as an indicator of scale accuracy.
9.Checktheoildrainbottle,andnotetheamountof
oilthatwasremovedfromtheA/Csystem.Thisis
theamountofnewoilthatmustbechargedinto
theA/Csystemafterevacuationiscomplete.
• Useonlynewoiltoreplacetheoilremovedduring
therecyclingprocess.
• Disposeofusedoilaccordingtolocal,state,and
federalregulations.
Recoveryiscomplete.Youarenowreadytoeither
advancetothechargeprocess,ortomakerepairsto
theA/Csystemfollowedbytheevacuationprocess.
Figure 6
Oil Drain
Bottle
Oil Inject
Bottle
Dye Inject
Bottle
Note: It is easier to remove the
oil drain bottle if the oil inject
bottle is removed rst.
Dye Inject
Oil Drain
Oil Inject
Operating Tips
After the RECOVER function is selected :
•
If system pressure is below 10 psi, until pressure
increases, the display reads
LOWRECOVERPRESSURE.
PLEASECHECKVALVESAND
CONNECTIONS.
SELECTYESTOCONTINUEWITH
RECOVERORSELECTVACUUM.
THEEXITKEYABORTSTHEFUNCTION.
Verify high- and low-side hoses are connected
and coupler valves are open. Select Yes to
recover, select Vacuum to bypass recover,
or select Exit.
• If 100 lbs. (45 kg) or more of refrigerant has
been recovered since the last lter-drier
change, the display reads
FILTERWEIGHTXXXLB
To meet SAE J-2788 requirements, it is
mandatory to replace the lter-drier after
150 lbs. (68 kg) of refrigerant has been
ltered. The unit gives a warning to replace
the lter when lter weight reaches 100 lbs.;
when lter weight reaches 150 lbs., the unit
locks out and ceases to operate. Refer
to instructions outlined in the Maintenance
section under Replace the Filter-Drier.