Owner's manual
© 2000 Robinair, SPX Corporation
4
Set-Up Instructions
INITIAL SET-UP
CAUTION!CAUTION!
CAUTION!CAUTION!
CAUTION! R-134a systems have special fittings (per SAE
specifications) to avoid cross-contamination with R-12 systems. Do
not attempt to adapt your unit for another refrigerant — system
failure will result! Read and follow all warnings at the beginning of
this manual before operating the unit.
CACA
CACA
CA
UTION! UTION!
UTION! UTION!
UTION! Avoid the use of an extension cord because the
extension cord may overheat. However, if you must use an
extension cord, use a No. 14 AWG minimum and keep the cord as
short as possible.
1. Lock both front casters of the unit by stepping on the cam brake levers, plug
the power cord into the power cord receptacle (Item 9 in the INST 0707
drawing on page 3). Turn on the MAIN POWER switch.
2. Press MENU.
3. Use the UP and DOWN arrows to select LANGUAGE SELECTION. Press
ENTER.
4. Use the UP and DOWN arrows to scroll through the language options and
press ENTER to select a language and exit LANGUAGE SELECTION.
5. Press MENU. Use the ARROW keys to go to SELECT AUTO RESTART.
Press ENTER.
6. Use the UP and DOWN arrows to toggle between AUTO RESTART ON and
AUTO RESTART OFF. Press ENTER to select.
NOTE: See the Operating Guidelines section of this manual for a description of
these functions.
7. Press MENU. Use ARROW keys to go to SELECT PROMPT. Press ENTER.
8. Use the UP and DOWN arrows to toggle between BASIC PROMPTS and
ADVANCED PROMPTS. Press ENTER to select.
NOTE: See the Operating Guidelines section of this manual for a description of
these functions.
IMPORTANT!
You must press
the MENU key to
access all the
functions.