User Manual
6
Set Tank Fill Level
Theoperatormayeitheraccepttheunit’spre-set
defaultweightof15lbs.(6.8kg)ofrefrigerantstoredin
theinternalstoragevessel(ISV),orchangetheamount
to accommodate the application.
Theunitdisplays
LEVEL:15.00LBS.
ENTER TANK FILL LVL
LIMIT:4TO17LBS.
PRESS START / YES TO SAVE
1.PressSTART / YES to accept the default amount, or
usethekeypadtoenteradesiredamountandpress
START / YES.
Add Oil to the Vacuum Pump
CAUTION: The vacuum pump is shipped without
oil in the reservoir. Failure to add oil to the vacuum
pump will damage the pump.
Theunitdisplays
ADD 5 OZ OF NEW OIL
TO VACUUM PUMP
START TO CONTINUE
1.Removethebrassplugfromthevacuumpumpoilll
port. See Figure 3.
2.
Attachtheexibletube/captotheoilbottle;pouronly
ve(5)ouncesofvacuumpumpoilintothellport.
Note: You will top off the oil in the next step as the
vacuum pump is running.
3.PressandreleasetheSTART / YES key. While the
vacuumpumpisrunning,slowlyaddoiluntilthe
levelrisestothecenterofthereservoir’ssightglass.
4.PresstheSTOP / NOkeytostopthevacuumpump,
andinstallthebrasspluginthellport.
5.PressSTART / YES to continue.
Setup
Figure 3
Sight
Glass
Fill Port
Vacuum Pump
Sight Glass
CAUTION: The unit is programmed
to run the setup procedure as outlined
here. To prevent personal injury, do
NOT operate the unit at any other time
without the brass plug installed, because
the vacuum pump is pressurized during
normal operation
.
Fill Port