User Manual

6
Set Tank Fill Level
Theoperatormayeitheraccepttheunit’spre-set
defaultweightof15lbs.(6.8kg)ofrefrigerantstoredin
theinternalstoragevessel(ISV),orchangetheamount
to accommodate the application.
Theunitdisplays
LEVEL:15.00LBS.
ENTER TANK FILL LVL
LIMIT:4TO17LBS.
PRESS START / YES TO SAVE
1.PressSTART / YES to accept the default amount, or
usethekeypadtoenteradesiredamountandpress
START / YES.
Add Oil to the Vacuum Pump
CAUTION: The vacuum pump is shipped without
oil in the reservoir. Failure to add oil to the vacuum
pump will damage the pump.
Theunitdisplays
ADD 5 OZ OF NEW OIL
TO VACUUM PUMP
START TO CONTINUE
1.Removethebrassplugfromthevacuumpumpoilll
port. See Figure 3.
2.
Attachtheexibletube/captotheoilbottle;pouronly
ve(5)ouncesofvacuumpumpoilintothellport.
Note: You will top off the oil in the next step as the
vacuum pump is running.
3.PressandreleasetheSTART / YES key. While the
vacuumpumpisrunning,slowlyaddoiluntilthe
levelrisestothecenterofthereservoir’ssightglass.
4.PresstheSTOP / NOkeytostopthevacuumpump,
andinstallthebrasspluginthellport.
5.PressSTART / YES to continue.
Setup
Figure 3
Sight
Glass
Fill Port
Vacuum Pump
Sight Glass
CAUTION: The unit is programmed
to run the setup procedure as outlined
here. To prevent personal injury, do
NOT operate the unit at any other time
without the brass plug installed, because
the vacuum pump is pressurized during
normal operation
.
Fill Port