User Manual
4
Menu Functions
1.PresstheMENU button on the keypad.
2.PresstheUP or DOWNarrowkeytoscroll
throughthemenuchoicesshownonthe
secondlineofthedisplay:
SELECT LANGUAGE
VERSION X.XX
SELECT UNITS
MAINTAIN VACUUM OIL
MAINTAIN FILTER
REFRIG. MANAGEMENT
MANUAL REFILL
ADJUST TANK FILL LVL
CALIBRATIONCHECK
SELECTBEEPERTONE
SERVICE MENU
HOSE FLUSH
DISPLAY TANK INFO
3.PressSTART / YES to make a choice from the
menu.PressSTOP / NOtopauseduringany
process,andSTOP / NOasecondtimetoexit
aprocess.
Introduction
Select Language
Operatormaychoosetohavepromptsdisplayedin
oneofthreelanguages:English,Spanish,orFrench.
Version X.XX
Displaystherevisionlevelofthesoftwareintheunit.
Select Units
The operator may choose to have test results
displayedinImperial(lb.),Imperial(lb.andoz.),or
Metric(kg).
Maintain Vacuum Oil
Formaximumvacuumpumpperformance,change
vacuumpumpoilafterevery10hoursofoperation.
Thismenuitemdisplayshowlongthevacuumpump
hasoperatedsincethelastoilchange,andallowsthe
usertoresetthevalueonceanoilchangeiscomplete.
RefertotheinstructionsoutlinedintheMaintenance
sectionunderChange Vacuum Pump Oil.
Maintain Filter
Thelter-drierremovesacid,particulates,andmoisture
fromtherefrigerant.TomeetSAEJ-2788requirements,
itismandatorytoreplacethelter-drierafter150lbs.
(68kg)ofrefrigeranthasbeenltered.Thismenu
itemshowshowmuchrefrigeranthasbeenltered
sincethelastlterchange,andallowstheuserto
resetthevalueoncealterchangeiscomplete.A
code,whichappearsonthelter,mustbeentered
intotheunittoensurecompliancewithSAEJ-2788.
RefertotheinstructionsoutlinedintheMaintenance
sectionunderReplace the Filter-Drier.
Refrig. Management
Displays the amount of refrigerant recovered,
charged,andreplenished(forthelifeoftheunit),
andltered(sincethelastlterchange).
Manual Rell
Usetotransferrefrigerantfromthesourcetanktothe
internalstoragevessel(ISV).Referto instructions
outlinedintheMaintenancesectionunderManually
Fill the ISV.
Adjust Tank Fill Lvl
When connected to a refrigerant source, the unit
maintainsapre-setamountofrefrigerantintheinternal
storagevessel(defaultis15lbs.).Thisvaluemaybe
adjustedupordowntosuittheuser’sneeds.Refer
toinstructionsoutlinedintheMaintenancesection
under Adjust Tank Fill Level.
Calibration Check
Use to verify internal scale calibration. Refer to
instructions in Maintenance section under Scale
Calibration Check.
Select Beeper Tone
Setthebeepertonetohigh(Beeper1),low(Beeper
2)ornone(Mute).
Service Menu
Robinairservicecenteruseonly.
Hose Flush
Flushesanyresidualoilfromtheunitforserviceof
vehicleswithdifferentoils.
Display Tank Info
Displaysinternalstoragevessel(ISV)pressureand
temperature.UsetochecktheISVforexcessive
pressure.
Stop / No
Button
Arrow
Keys
Start / Yes
Button
Menu
Button