User Manual

20
Replacement
Component Part No.
Filter -Drier 34724
Calibration Weight 540066
Service Coupler Set
(high- and low-side couplers) 18192
ServiceHoseSet
(high- and low-side hoses) 34722
Vacuum Pump Oil
(case of 12 quarts) 13203
Replacement Parts
Maintenance
Vacuum Pump Oil
(case of 4 gallons) 13204
Maintenance Kit 13172
VinylDustCover(optional) 17492
VehicleDatabase(optional) 34411
High-sideStoragePort 546882
Low-sideStoragePort 546883
TankFillHoseFilter 10233
Replacement
Component Part No.
Inspect the unit periodically for leaks.
The manufacturer does not reimburse for
lost refrigerant.
Check for Leaks
Checktheunitforleakseverythreemonths,oras
speciedbylawinyourjurisdiction.
1.Turnoff,anddisconnectthepowercordfromthe
outlet.
2.
Openthereardoor;removetopcoverandfront
panel.
3.
Usealeakdetectortoprobeallconnectionsfor
refrigerantleaks.Tightenttingsifaleakisindicated.
4.Reassemblethebodypanels,andclosetherear
door.
Adjust Tank Fill Level
Whenconnectedtoarefrigerantsource,theunit
maintainsadefaultvalueof15lbs.ofrefrigerantinthe
internalstoragevessel.Thisvaluemaybeadjustedup
ordowntosuittheapplication.
1.PressMENU.
2.Usethearrowkeystoscrollthroughthemenuto
ADJUST TANK FILL LVL,andpressSTART / YES.
Theunitdisplays
LEVEL:15.00LBS.
ENTER TANK FILL LVL
LIMIT:4TO17LBS.
PRESS START / YES TO SAVE
3.Usethekeypadtoenteravaluebetween4lbs.and
17lbs.,andpressSTART / YES.