User Manual

15
539602 Rev. H June 11, 2013
Circuit
Breaker
Figure 10
Back View
Maintenance
General Maintenance
1.Onaregularbasis,wipeofftheunitusingaclean
clothtoremovegreaseanddirt.
2.
Periodicallycheckinternalcomponentsforleaks;over
time,ttingscanloosenastheunitismoved.Open
thedoorpanel,andtracelinesusingaleakdetector.
Checkconnectionsonthebackoftheunit.Tighten
anyloosettingsorconnectionsyoumaynd.
Electrical Protection
Theunitisequippedwitha15ampcircuitbreakeron
thebackpanel.SeeFigure10.Ifthebreakertrips,its
buttonwillpopout.Atrippedcircuitbreakerwillcause
theunittoloseallpower.
Pressthecircuitbreakerbuttontoreset.
Manually Fill the
Internal Storage Vessel (ISV)
Thismenuitemisusedtotransferrefrigerantfroma
sourcetanktotheinternalstoragevessel.
Note: If a refrigerant source tank remains connected to
the unit during normal operation, the correct amount of
refrigerant will automatically be maintained in the ISV.
The ISV may be manually relled, if necessary.
1.PressMenu,andusearrowkeystoselectMANUAL
REFILL.PressSTART / YES. Theunitdisplays
CONNECT SOURCE TANK
STARTTOBEGIN
2.Connectthellhosetoafullsourcetank,andopen
thesourcetankvalve.
3.Installthesourcetank,andsecureittotheunit
withthesourcetankstrapinsuchawaythatliquid
refrigerantissuppliedtotheconnection.
4.PressSTART / YEStobegin.Thedisplayshows
TANK FILL IN PROGRESS
TRANSFERXXLBS
5.Theunitautomaticallystopswhenthepresettankll
levelisreached,orpressSTOP / NOtoexit.
Figure 11
Side View
Fill Hose
Power
Cord
Source
Tank
Strap
Low- and
High-Side
Hoses