User guide
6
Set Tank Fill Level
Theoperatormayeitheraccepttheunit’spre-set
defaultweightof15lbs.(6.8kg)ofrefrigerant
storedintheinternalstoragevessel(ISV),
orchangetheamounttoaccommodatethe
application.
Theunitdisplays
LEVEL:15.00LBS.
ENTERTANKFILLLVL
LIMIT:4TO17LBS.
PRESSSTART/YESTOSAVE
1.PressSTART / YEStoacceptthedefault
amount,orusethekeypadtoenteradesired
amountandpressSTART / YES.
AddOiltotheVacuumPump
CAUTION: The vacuum pump is shipped
without oil in the reservoir. Failure to add oil to
the vacuum pump will damage the pump.
Theunitdisplays
ADD5OZOFNEWOIL
TOVACUUMPUMP
STARTTOCONTINUE
1.Removethebrassplugfromthevacuumpump
oilllport.SeeFigure3.
2.
Attachtheexibletube/captotheoilbottle;pour
only ve (5) ouncesofvacuumpumpoilinto
thellport.Note: You will top off the oil in the
next step as the vacuum pump is running.
3.PressandreleasetheSTART / YESkey.While
thevacuumpumpisrunning,slowlyaddoiluntil
thelevelrisestothecenterofthereservoir’s
sightglass.
4.PresstheSTOP / NOkeytostopthevacuum
pump,andinstallthebrasspluginthellport.
5.PressSTART / YEStocontinue.
Setup
Sight
Glass
Fill Port
Vacuum Pump
Sight Glass
CAUTION: The unit is programmed
to run the setup procedure as outlined
here. To prevent personal injury, do
NOT operate the unit at any other
time without the brass plug installed,
because the vacuum pump is
pressurized during normal operation
.
Fill Port
Figure 3