User guide
5
560826 Rev. D, August 23, 2013
Setup
Unpack the Accessory Kit
Unpacktheaccessorykitfromthebag,and
removetheplasticpackaging.Thekitconsistsof
• Acalibrationweight.
• Vacuumpumpoil,oilllercap,andtube.
•
Plasticpouchcontainingawarrantycard(to
becompletedandmailed),applicableMSDS
sheets,aservicecenterlisting,andanenvelope
ofMobileAirConditioningSociety(MACS)
information.
Important: You must complete and mail
the MVAC Certication Form and your
technicians must be certied with the
Environmental Protection Agency (EPA)to
operate this equipment.
Power Up the Unit
1.
Unwindthepowercordfromthehandle,and
plugitintoacorrectvoltageoutlet.SeeFigure
1.
2.
Turnonthemainpowerswitch.Thersttime
theunitispoweredup,itdisplaystheinitial
setupmode.
Select a Language – English
Seleccionar Idioma – Espanol
Selection Langue – Francais
Theoperatormaychoosetohaveprompts
displayedinoneofthreelanguages:English,
Spanish,orFrench.
1.
UsetheUPorDOWNarrowkeytotoggle
throughthechoicesofEnglish,Spanish,or
French.RefertoFigure2.
2.
PressSTART / YEStoselectthedisplayed
language.
Select Operating Units
Theoperatormaychoosetohavetestresults
displayedinImperial(lb.,orlb.andoz.)orMetric
(kg)units.
1.
UsetheUPorDOWNarrowkeytotoggle
throughthechoicesofIMPERIALUNITSor
METRICUNITS.
2.PressSTART / YEStoselectthedisplayed
operatingunitchoice.
Arrow
Keys
Start / Yes
Button
Figure 2
Stop / No
Button
Power
Cord
Main
Power Switch
Figure 1
CAUTION:
R-134a systems have
special ttings (per SAE specications)
to avoid cross-contamination with R-12
systems. DO NOT adapt your unit for a
different refrigerant — system failure
will result.