User guide
20
5.ThedisplayreadsPLEASEREPLACEFILTER.
Openthereardooroftheunitandunscrewthe
oldlter.SeeFigure15.
6.
Lookatthenewlter—verifybotho-ringsare
lubricatedandcorrectlylocatedinthegrooves.
SeeFigure16.Threadthenewlterintoplace.
PressSTART / YES.
7.Closethedoor.PressSTOP / NOtoexit.The
lter-drierreplacementisnowcomplete.
Replace the Filter-Drier contd.
Maintenance
Filter-
Drier
RearView
(withoutshroud)
Adjust Tank Fill Level
Whenconnectedtoarefrigerantsource,theunit
maintainsadefaultvalueof15lbs.ofrefrigerant
intheinternalstoragevessel.Thisvaluemaybe
adjustedupordowntosuittheapplication.
1.PressMENU.
2.Usethearrowkeystoscrollthroughthemenu
toADJUSTTANKFILLLVL,andpressSTART /
YES.Theunitdisplays
LEVEL:15.00LBS.
ENTERTANKFILLLVL
LIMIT:4TO17LBS.
PRESSSTART/YESTOSAVE
3.Usethekeypadtoenteravaluebetween4lbs.
and17lbs.,andpressSTART / YES.
Figure 15
O-rings
Figure 16