User guide

17
560826 Rev. D, August 23, 2013
Maintenance
General Maintenance
1.Onaregularbasis,wipeofftheunitusinga
cleanclothtoremovegreaseanddirt.
2.
Periodicallycheckinternalcomponentsfor
leaks;overtime,ttingscanloosenastheunit
ismoved.Openthedoorpanel,andtracelines
usingaleakdetector.Checkconnectionson
thebackoftheunit.Tightenanyloosettingsor
connectionsyoumaynd.
Electrical Protection
Theunitisequippedwitha15ampcircuitbreaker
onthebackpanel.SeeFigure12.Ifthebreaker
trips,itsbuttonwillpopout.Atrippedcircuit
breakerwillcausetheunittoloseallpower.
Pressthecircuitbreakerbuttontoreset.
Manually Fill the
Internal Storage Vessel (ISV)
Thismenuitemisusedtotransferrefrigerantfrom
asourcetanktotheinternalstoragevessel.
Note: If a refrigerant source tank remains
connected to the unit during normal operation, the
correct amount of refrigerant will be automatically
maintained in the ISV. The ISV may be manually
relled, if necessary.
1.PressMenu,andusearrowkeystoselect
MANUALREFILL.PressSTART / YES. The
unitdisplays
CONNECTSOURCETANK
STARTTOBEGIN
2.Connectthellhosetoafullsourcetank,and
openthesourcetankvalve.
3.Installthesourcetank,andsecureittotheunit
withthesourcetankstrapinsuchawaythat
liquidrefrigerantissuppliedtotheconnection.
4.PressSTART / YEStobegin.Thedisplay
shows
TANKFILLINPROGRESS
TRANSFERXXLBS
5.Theunitautomaticallystopswhenthepreset
tanklllevelisreached,orpressSTOP / NOto
exit.
Figure 13
SideView
Fill Hose
Power
Cord
Source
Tank
Strap
Low- and
High-Side
Hoses
Circuit
Breaker
Figure 12
BackView