User guide

13
560826 Rev. D, August 23, 2013
Operating Instructions – Automatic
Theautomaticfunctionallowsausertoprogram
anautomaticrecovery,vacuum,leaktest,and/or
chargesequence.Theusermaychoosetoskip
anystepintheautomaticoperationduringthe
programming.Atotalautomaticsequencemay
takeanhourtocomplete.
Note: Oil recovered during the recovery cycle can
be manually injected by the user before or after
the charge cycle using a separate oil inject tool.
1.
Connectthehigh-andlow-sideservicehosesto
theA/Csystem,andopenthecouplervalveson
thehoses.
2.PresstheAUTOMATICbutton.SeeFigure9.
3.Theunitasksifarecoveryisneeded.Press
STOP / NOtoskiptherecoverycycle;press
START / YEStoaccept.IfNOisselected,the
unitasksforvacuumandtimeofvacuum.
4.
Theunitasksifaleaktestisneeded.PressSTOP
/ NOtoskiptheleaktest;pressSTART / YESto
accept.
5.Theunitasksifachargeisneeded.Press
STOP / NOtoskipthechargecycleand
proceedtoStep6;pressSTART / YESto
accept.
IfSTART/YESispressed,theunitdisplays
CHARGEHYBRIDW/AN
ELECTRICCOMPRESSOR
THATUSESPOEOIL?
YESNO
Ifservicingahybrid,pressSTART / YES.
Connectservicecouplerstothestorageport
connectionsshowninFigure10,andopen
thecouplervalves.PressSTART / YESagain
tobeginahoseushprocedure.Whenhose
ushingiscomplete,connecttheservicehoses
tothevehicleserviceports,andpressSTART /
YEStocontinue.PressCHARGEagaintotoggle
betweenhigh-orlow-sidecharge,orboth.
AcceptthedefaultweightbypressingSTART
/ YES,ortypeinadesiredweightusingthe
numberkeysandpressSTART / YES.
Automatic
Function
Figure 9
Figure 10
Storage Port
Connections