Instruction Manual

13
R-134a Smart Cart
®
Automatic A/C Charging Station
Symptom Cause Cure
Station unplugged Plug station into power
source
No power at wall outlet Locate problem with outlet or
change outlets
Vacuum pump unplugged Plug pump into power source
Vacuum time not entered Program required vacuum
time
• Defective vacuum pump • Remove and replace pump
Faulty components Call factory
Transfer stopped or Start A/C system and pull
too slow rest of refrigerant into system
(Step 6 in “To Use Automatic
Vacuum/Charge Cycle”)
Tank safety strap too tight Loosen the safety strap
Refrigerant supply empty Replace the refrigerant tank
or call factory
Refrigerant supply empty Replace the refrigerant tank
• Discharge valve open • Close discharge valve
• Low side valve closed • Open low side valve
• Pump oil contaminated • Flush and change pump oil
• Hose gasket damaged • Replace gasket or hose
• Charging line loose • Check connections
• Manifold leaking • Check connections
Pump’s Iso-valve closed Open Iso-valve
Overloaded or broken Check tank weight, recali-
scale brate if necessary, or call
factory
Trouble-
Shooting
Tips
No power when
POWER switch is on
no display showing
Vacuum pump does not
start
Audible tone sounds
and CHECK REFRIG-
ERANT message
displays during
refrigerant transfer
Refrigerant doesnt flow
or REFRIGERANT
message doesnt
display
Vacuum pump runs, but
low side gauge does not
register an appropriate
vacuum
ERR5