Specifications

Evacuation
HVAC
17
HVAC
18
Evacuation
VacuMaster™ Economy
Vacuum Pumps
• Performance tested to meet
Robinair’s high standards.
• Power and capacity for a wide range
of service applications.
• High CFM rating for fast, thorough
evacuation.
• Two-stage rotary vane design.
Two-stage Design – Cleans the
system more thoroughly than a single-
stage pump; the second stage starts
pumping at a lower pressure so you
can pull a deeper, ultimate vacuum.
Factory
Free Air Micron No. of Motor
Model Displacement Rating Stages Intake Fitting Oil Capacity Size Voltage Weight Dimensions
Domestic Models
15150 1.5 CFM 50 microns 2 1/4" MFL and 3/8" Acme 7.4 oz. (219 ml) 1/4 hp 115V 60Hz 22 lbs. (10 kg) 9.5" H x 4.75" W x 12.5" L
3/8" FFL x 1/2" Acme adaptr. 240 mm x 120 mm x 315 mm
15300 3 CFM 40 microns 2 1/4" MFL and 3/8" MFL 7.5 oz. (220 ml) 1/3 hp 115V 60Hz 28 lbs. (12.5 kg) 10" H x 5" W x 13" L
3/8" FFL x 1/2" Acme adaptr. 255 mm x 123 mm x 336 mm
15500 5 CFM 40 microns 2 1/4" MFL and 3/8" Acme 7.5 oz. (220 ml) 1/3 hp 115V 60Hz 28 lbs. (12.2 kg) 10" H x 5" W x 13" L
3/8" FFL x 1/2" Acme adaptr. 255 mm x 123 mm x 336 mm
15800 8 CFM 40 microns 2 1/4" MFL and 3/8" MFL 18.6 oz. (550 ml) 1 hp 115V 60Hz 37 lbs. (16.8 kg) 16" H x 6" W x 10" L
406" mm x 152mm x 254mm
International Models
15301 71 liters/minute 40 microns 2 1/4" MFL and 1/2" MFL 7.5 oz. (220 ml) 1/3 hp 220V 50Hz 28 lbs. (12.5 kg) 10" H x 5" W x 13" L
3 CFM 3/8" FFL x 1/2" Acme adaptr. 255 mm x 123 mm x 336 mm
15501 118 liters/minute 40 microns 2 1/4" MFL and 1/2" Acme 7.5 oz. (220 ml) 1/3 hp 220V 50Hz 28 lbs. (12.5 kg) 10" H x 5" W x 13" L
5 CFM 3/8" FFL x 1/2" Acme adaptr. 255 mm x 123 mm x 336 mm
Oil Drain Valve Positioned at the
bottom of the oil reservoir and angled
for faster, more complete draining.
Oil Fill Port Makes adding oil simple
since the port is accessible from the
front or either side. The sight glass on
the front of the pump shows you when
enough oil has been added.
Heavy-Duty MotorHigh torque
design for easy startup and
efficient operation.
Die-Cast Aluminum Housing – Cast
aluminum housings make the pumps
lightweight but durable.
14777
Compact Electronic
Thermistor Vacuum Gauge
• Compact, pocket-size – 2.5" x 3".
• Takes guess work out of evacuation
– accurately indicates when system
is ready for recharge.
• Designed for use under high vacuum,
reads down to 10 microns.
• Easy-to-read LCD, automatically
registers smaller numeric segments
as system pulls-down.
• 6' long lead and magnetic mounting
strip – allows for convenient, easy to
read, positioning.
Range 25,000 to 10 microns
Vacuum Fitting 1/4" MFL
Power Supply One 9V battery (included)
Specifications
Specifications
Thermistor Vacuum Gauge
• Solid-state instrument constantly
monitors and visually indicates the
vacuum level in 10 segments
from atmosphere to 50 microns.
• LCD screen can be read even in
direct sunlight and minimizes battery
consumption.
• There are no adjustments to make,
no calibrations for atmospheric
pressure or altitude.
• Durable carrying case protects
the instrument and has a built-in
compartment for storing the 24"
charging hose (included).
14830A
14010A
Thermistor Vacuum Gauge
• Large analog meter – clearly marked
for easy reading of micron levels.
• Indicates actual vacuum level.
• Measures from 25,000 to 0 microns.
• Two operation modes – select
between the null method for greatest
accuracy or direct meter reading
for continuous monitoring of the
evacuation process.
• Proven bridge circuit compensates
for changes in ambient temperature
from 30º to 120º F (-1º to 49º C) and
also for variances in battery voltage.
• Rugged Carrying Case.
Range 25,000 to 0 microns
Vacuum Fitting 1/4" FFL
Power Supply Six "C" cell batteries
Specifications
Optional Accessories Part No.
Optional A/C Power Adapter
17160
Replacement Parts
(supplied with product)
Part No.
Replacement Thermistor Tube
17162
TIF 9450D
Digital Micron Gauge
U.S. Patent # 5,136,8855
• Patented sensor technology –
requires no calibration for fluctuating
ambient and/or sensor housing
temperatures.
• Not affected by the specific gas
being evacuated.
• Liquid Crystal Display (LCD) – Reads
500,000 to 200 microns.
• Dual power supply – 9V battery or
auxiliary A/C adapter (not included).
• Three foot sensor cord.
• Built into ABS Carrying Case.
• One year warranty.
Range
500,000 to 200 microns
Hg (auto ranging)
Resolution
100/10/1 microns Hg
Vacuum Fitting
1/4" FFL
Power Supply
One 9V battery or 9VDC
optional adapter
Battery Life
8 hours (Alkaline)
Probe Cord Length
36" (91.4 cm)
Operating Temp
32º to 125º F
(0º to 52º C)
Specifications
Replacement Parts
(supplied with product)
Part No.
Sensing Probe Assembly
TIF9453
Connector hose with Filter
TIF9454
Charging/Scales
Range 25,000 to 50 microns in 10 segments
Power
Supply
Four "D" cell batteries (not included)
or optional A/C adapter
Display Custom LCD, 10 segments
Weight 2.38 lbs. (1.08 kg) without batteries
Dimensions 10" H x 7.5" W x 3.375" D (25.4 cm x
19 cm x 8.6 cm)
Oil Injector
• Syringe-Type, allows you to add
refrigerant oil to a fully charged
A/C system.
• Simply fill the barrel with the amount
of oil required.
• Check valve prevents any "back
flow" of refrigerant.
• 1/4" SAE fitting.
• Capacity – 1/2 ounce (15 ml).
16258
Heater Blanket
• Speeds charging by raising
temperature, thus creating a positive
pressure difference between tank
and A/C system.
• Fits 30 and 50 pound refrigerant
tanks.
• Includes Thermostat – set at
125º F (55º C).
• Safety thermal cut-off switch
protects against overheating.
• 300 watts, 2.6 amps.
10994
(Tank not included)
Replacement Parts
(supplied with product)
Part No.
Replacement Plunger
16262
Replacement O-Ring for Plunger
(pkg. of 5)
16267
Optional Accessories /
Replacement Parts
Part No.
Adapter
44885
Oil Pump Rebuild Kit
18171
Cap and Seal Assembly
44884
Refrigerant Oil Pump
• Oil-Pump design allows you to
add refrigerant oil to a
system under pressure.
• Designed for larger systems.
• Siphon hose allows for the
removal of old oil, preventing
over-charging.
• Pump universally mounts
directly to one-gallon containers.
• Allows the pumping of oil directly
from the container, keeping oil free
from dirt & moisture.
• Pump can remain mounted on oil
container during storage.
• Oil is pumped at a rate of 3 ounces
(90 ml) per stroke.