Owner manual
Model 17800B / 17801B Recovery/Recycling/Recharging Unit
11
ENGLISH
HOLD/CONT
CAUTION: If the A/C system pressure is 25 psi or less, the
message “CH-P” appears on the display to alert you not to attempt
recovery from an empty system. Do not press HOLD/CONT to
continue the recovery process unless you know the A/C system
contains refrigerant.
HOLD/CONT
CAUTION: Drain the oil from the separator only after each
recovery.
Do not completely depressurize the oil separator; immediately close
the valve when oil is completely drained in the next step. The lower
right corner of the display will indicate “OIL (OUNCES)” as a reminder.
slowly
If the recovery tank lls completely:
• The compressor shuts off; the digital display shows the message “FULL.”
• Change the tank.
Weight Example
Operating Instructions
HOLD
OIL(OUNCES)
HOLD
LBS
RECOVER
Hold
HOLD
LBS
RECOVER
CL-L
HOLD
CH-P
CPL
8.30
FULL
FLASHES