Specifications

© 2001 Robinair, SPX Corporation
8
Before starting the set up procedures, open the system oil drain valve and allow the unit
to depressurize.
1. Plug the unit into a proper voltage outlet.
CAUTION! Avoid the use of an extension cord because the extension cord
may overheat. However, if you must use an extension cord, use a No. 14 AWG
minimum and keep the cord length to 25 feet (7.6 meters) or less.
2. Be sure the oil drain valve on the side of the unit is in the CLOSED position.
3. Turn on the unit. The display flashes “door.” Slide the lockout door (in the upper
left corner of the back of the unit) to expose
the
1
/
4
” flare fittings for R-12, or the
1
/
2
” Acme fittings for R-134a then press
SHIFT/RESET to continue.
4. Connect either of the automotive hose sets as follows:
Connect the 36” red hose to the
RED fitting on the back of the unit
Connect the 36” blue hose to the
BLUE fitting on the back of the unit
Connect the 36” yellow hose to the
YELLOW fitting on the back of the
unit
CAUTION! R-134a automotive
systems have
1
/
2
” Acme fittings (per
SAE specifications) to avoid cross-contamination with systems using
1
/
4
” flare fittings. Do not attempt to adapt your unit for the other refrigerant —
system failure will result!
Diagram of Hose Connections
Lockout Box
INST0920
HIGH
LOW
RED
BLUE
YELLOW
Set Up Instructions
(R-134a shown—
R-12 same order
and colors)