Specifications

Model 17800B Recovery/Recycling/Recharging Unit
45
Runs but will not shut off
Problem: Oil drain valve is open
Solution: Close the oil drain valve
Problem: There is a leak in the A/C-R system
Solution: Locate and repair all system leaks
Problem: Hoses are not properly connected to the vehicle
Solution: Check hose connections
Problem: Oil return solenoid is open
Solution: Replace the oil return solenoid
RECYCLING OPERATION
Compressor does not start or stops prematurely
Problem: Power cord is not plugged in or there is no power at plug
Solution: Check circuit for power
Problem: Tank valves are closed
Solution: Open both valves and be sure hoses are properly
connected to the tank
Problem: “CH-F” message on digital display
Solution: Remove and replace the filter-drier (see Replacing the Filter-
Drier), and be sure to pull a vacuum before continuing
Refrigerant does not flow
Problem: Refrigerant supply empty or low
Solution: Add refrigerant to the tank
Problem: Tank valves are closed
Solution: Open both valves and be sure hoses are properly
connected to the tank and the unit
Troubleshooting