RECOVERY OPERATION
Compressor does not start
Problem: Main power switch is off
Solution: Turn on switch
Problem: Power cord is not plugged in or there is no power at plug
Solution: Check circuit for power
Problem: “FULL” message shows on digital display
Solution: Change tanks (see Installing a Tank and Pulling A Vacuum)
Problem: “HI-P” message shows on digital display
Solution: Be sure tanks valves are open and hoses are properly connected to the
tank, or
Check for air in the tank (recycle tank to purge any air), or
Check the scale calibration (see Checking the Scale Accuracy)
Note: If "HI-P" message does not disapear in 20 minutes the pressure will
have to be released manually. Recover the pressure from the HI-P Access
Port shown on page 4 in the Diagram of Units Components - Internal View.
Problem: “CH-F” message on digital display
Solution: Remove and replace the filter-drier (see Replacing the Filter-
Drier), and be sure to pull a vacuum before continuing
Runs for a short time but does not complete recovery
Problem: Tank valves are closed
Solution: Open both valves and be sure hoses are properly
connected to the tank
Problem: Manifold valves are closed
Solution: Open both valves