position. Slide the refrigerant lockout panel (located on the back of the unit, top left
corner) to expose the fittings for the selected refrigerant type.
OIL/drn (Flashes alternately) Drain; open the oil drain valve to relieve the
pressure in the unit.
FIL Compressor oil and filter/drier change procedures are being per-
formed.
FULL The tank is full; recovery stops automatically.
HI-P High pressure; the unit pressure is greater than 435 psi.
OIL Change vacuum pump oil; it has been 10 hours since the last oil
change.
R12 R-12; indicates R-12 or other refrigerant type requiring
1
/
4
” flare fittings.
SCAL Scale problem; the scale is broken or disconnected, or the tank has
exceeded 75 pounds gross weight.
U-HI High pressure to vacuum pump; prevents blowing
refrigerant through the vacuum pump. To relieve
pressure, perform a recovery process (see the Operating Instruc-
tions).