Segment A — Indicates in which mode the unit is operating:
PROGRAM — The unit is in the programming mode, which allows you to pro-
gram vacuum time and refrigerant weight or to review the existing program.
HOLD — This mode is used to change a refrigerant tank or to interrupt the
vacuum/charging/recovery cycles.
AUTOMATIC — Indicates that the unit is running in a given cycle and will
automatically stop when the cycle is complete. One exception: the recycling process
must be stopped by pressing HOLD/CONT.
Segment B — Indicates that the unit is either evacuating the A/C-R system or recover-
ing, recycling, or recharging refrigerant or that the unit is ready to be programmed for
one of the following functions.
(Use the chart on the next page as a quick reference for interpreting Segment B mes-
sages.)
VACUUM
With PROGRAM, indicates that the unit is ready to be programmed for vacuum.
With AUTOMATIC, indicates that the vacuum pump is running; the number
displayed counts down in minutes and seconds, showing the amount of time remain-
ing.
With HOLD, indicates that HOLD/CONT was pressed to interrupt the vacuum
cycle.
RECYCLE
With AUTOMATIC, indicates the unit is recycling refrigerant
from the tank.
CHARGE
With PROGRAM, indicates that the unit is ready to be
programmed for the amount of refrigerant to be charged into the
A/C-R system; on the keypad enter the charge in pounds and hundredths of a
pound or kilograms, depending on the measurement mode selected.
With AUTOMATIC, indicates the unit is charging refrigerant into the A/C-R system;
the number shown on the digital display counts down, showing the remaining amount
of refrigerant to be dispensed.
With HOLD, indicates that HOLD/CONT was pressed to interrupt the charging
cycle; the number shown on the digital display is the amount of refrigerant remaining
Operating Guidelines