80S2
WARNING
PRESSURIZED TANK CONTAINS LIQUID REFRIGERANT. OVERFILLING OF THE TANK MAY CAUSE VIOLENT EXPLOSION
AND POSSIBLE INJURY OR DEATH. Safety devices requires the use of only authorized refillable refrigerant tanks. This includes
Robinair Part Numbers 17506 and 34750 (50lb.) tank. Do not recover refrigerants into a non-refillable storage container! Federal regulations
require refrigerant to be transported only in containers meeting DOT spec. 4BW or DOT spec. 4BA.
ALL HOSES MAY CONTAIN LIQUID REFRIGERANT UNDER PRESSURE. Contact with refrigerant may cause injury. Wear proper
protective equipment, including safety goggles. Disconnect hoses with extreme caution.
HIGH VOLTAGE ELECTRICITY INSIDE PANELS. RISK OF ELECTRICAL SHOCK. Disconnect power before servicing unit. Refer
to the operating manual.
TO REDUCE THE RISK OF FIRE, avoid the use of an extension cord because the
extension cord may overheat. However, if you must use an extension cord, the cord shall be No. 14 AWG minimum and keep the cord as
short as possible. Do not use this equipment in the vicinity of spilled or open containers of gasoline or other flammable substances.
Use this equipment in locations with mechanical ventilation that provides at least four air changes per hour or locate the equipment at least
18 inches off the floor.
Make certain that all safety devices are functioning properly before operating the unit. Before operating, read and follow the instructions and
warnings in the operating manual.
CAUTION: RISK OF INJURY. THIS EQUIPMENT SHOULD ONLY BE OPERATED BY CERTIFIED PERSONNEL. Operator must
be familiar with A/C systems, refrigerants and the dangers of pressurized components.
Use this unit only with R-12, R-134a, and ARI 98 Refrigerant Classes III and IV systems only. This unit is not designed for
any other purpose than recovering or recycling refrigerants! Do not mix refrigerant types!
Additional health and safety information may be obtained from refrigerant and lubricant manufacturers.
ATTENTION!
Ce réservoir sous pression contient du frigorigène liquide. S’il est surchargé, ce réservoir peut exploser et causer des blessures ou la
mort.
ATTENTION. Débrancher avant la maintenance.
ATTENTION. Pour réduire les risques d’incendie, ne pas utiliser de cordon prolongateur de section inférieure à 14 AWG de facon à
éviter la surchauffe du cordon.
ATTENTION. Utiliser seulement du frigorigène R-12 and R-134a.
OPERATING NOTES
Drain the System Oil Separator at the end of each recovery. The display will indicate when a filter-drier and
vacuum pump oil change are required except if you are recovering from a burnout system. Then the filter-
drier should be changed at the completion of that job. When switching refrigerant types, the unit must
always be self-cleared.
Non-condensables can be purged from the refillable tank during the recycling procedure. Get the tempera-
ture of the refrigerant you are recycling from the air purge gauge. Look at the pressure-temperature chart to
find what the pressure should be at that temperature and compare it to what the air purge gauge pressure is.
If the pressure on the air purge gauge exceeds the desired pressure by more than 10 psi, open the gauge
for 30 seconds, then close it and re-check the pressure. Continue as needed during the recycling
procedure.
Design Certified by
Underwriters
Laboratories Inc.,®
to meet SAE-J-1770
for recycling R-134a
and R-12 using
common refrigera-
tion circuits.
Model: 17800B
Volts: 115V 60 Hz
Amps: 12.0
Refrigerants: R-12, R-134a,
ARI 98 Class III, and ARI 98 Class IV
Design Pressure: High 382 psig
Low 171 psig
Serial No.:
Date Code:
Refrigerant Recovery,
Recycling, and Recharging
Station
ROBINAIR
This equipment is protected by one or more of the following U.S. and foreign patents: US 4,523,897; 4,688,388; RE: 33,212;
4,768,347; 4,805,416; 4,878,356; 4,938,031; 5,005,369; 5,005,375; 5,038,578; 5,042,271; 5,063,749; 5,095,713; 5,181,391; 5,203,177;
5,231,842; 5,248,125; 5,493,869; 5,603,223; AUS 609,240; AUS 613,058; AUS 622,833; BRA P1 8803612; CAN 1,311,621; CAN
1,311,622; CAN 1,331,922; CAN 2,012,620; CAN 2,026,348; EUR 0 315 296 B1;
EUR 0 329 321 B1; EUR 0 437 021 B1; MEX 16028; SAF 88/4981. Other U.S. and Foreign Patents Pending.
Manufactured by Robinair, SPX Corporation, Montpelier, OH 43543-1952
123941 (04/01) Printed in U.S.A.
LISTED