○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Operating Manual Model 176802K Refrigerant Recovery Station
Model: 176802K Refrigerant Recovery Station Refrigerant: Mixed Serial No.: Date Code: WARNING TO PREVENT PERSONAL INJURY AND/OR EQUIPMENT DAMAGE : BEFORE OPERATING THE REFRIGERANT RECOVERY STATION, READ AND FOLLOW THE OPERATING INSTRUCTIONS AND SAFETY PRECAUTIONS IN THIS MANUAL. This station should only be operated by qualified personnel. The operator must be familiar with A/C-R systems, refrigerants, and the dangers of pressurized components.
Introduction TABLE OF CONTENTS Glossary of Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Setup Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Diagram of Station’s Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Diagram of Control Panel . . . . . . . . . . . . . . . . . . . . .
Setup Instructions To initially set up the station for operation: 1. Unpack all components and verify you have the following: (1) (1) (1) 50-pound refrigerant tank 96" Blue Enviro-Guard® Hose for R-12 96" Blue Enviro-Guard® Hose for R-134a (with adapter) Please read this operating manual, and fill out and return the warranty registration card. NOTE: The numbers in parentheses correspond to the callouts shown in the diagrams on page 5. 2.
Set Up Instructions 5 6 4 3 7 2 4 8 5 ROBINAIR 3 2 9 1 10 INST0195 Diagram of Station’s Components 1. Drain for Drip Pan 8. Blue Recovery Hoses 2. Black 3/8" Discharge Hose 9. Float Cable 3. Accumulator Oil Drain 10. R-134a Service Coupler 4. Lubricator 11. Inlet Pressure Gauge 5. Battery Clips 12. Tank Pressure Gauge 6. Regulator 13. Control Panel Valve 7. Inlet Ports 14.
Operating Instructions WARNING Wear safety goggles when working with refrigerants. Read and follow all warnings at the beginning of this manual before operating this machine. Connecting hoses to the wrong ports may cause personal injury and/or damage to the equipment. Check your vehicle’s A/C system operating manual for the correct hookup. Handle battery connection cables with extreme caution — batteries generate explosive gases during normal battery operation.
Operating Instructions Sometimes refrigerant will pool inside the system. When the compressor is turned off, ambient heat will vaporize this pooled refrigerant, causing system pressure to rise again. The recovery process should be repeated until the system remains at a vacuum for at least two (2) minutes. 9. When the recovery process is complete, close the tank’s valve, close the hose valve, and disconnect the recovery hose from the vehicle. 10.
Maintenance Instructions NOTE: Numbers in parentheses correspond to callouts shown in the diagrams on page 5. This station is designed to operate with a minimal amount of maintenance. 1. For correct lubrication of the air motor, the oil level in the air line lubricator (4) on the back of the station must be maintained above the bottom of the dip tube inside the lubricator’s bowl. Fill with 3/4 oz. (22 ml) of pneumatic air line oil or detergent SAE #10 motor oil.
Troubleshooting Tips Unit runs for short time before building up high tank pressure, or compressor stalls. Problem: Tank valve closed. Solution: Open the tank valve with 3/8" adapter, and open the 3/8" hose valve. Compressor stalls during recovery. Problem: Insufficient supply of air pressure. Solution: Supply air pressure should be a minimum of 120 psi and a maximum of 200 psi. Problem: Insufficient supply of air volume. Solution: Minimum volume of supply air should be 10 CFM at 120 psi.
WARRANTY This product is warranted to be free from defects in workmanship, materials, and components for a period of one year from date of purchase. All parts and labor required to repair defective products covered under the warranty will be at no charge. The following restrictions apply: 1. The limited warranty applies to the original purchaser only. 2. The warranty applies to the product in normal usage situations only, as described in the operating manual.
Notes Model 176802K Scavenger™ Recovery Unit 11
☎ For assistance in servicing or using the Scavenger™ Refrigerant Recovery Station, call the toll-free Technical Support Line, 800-822-5561, in the U.S. and Canada, or visit our web site at www.robinair.com. In all other locations, contact your local distributor. To help us serve you better, be prepared to provide the model number, serial number, and date of purchase. To validate your warranty, complete the warranty card attached to your unit and return it within ten days from date of purchase.