User guide

23
Specications
Sample Parameters Vapor only, oil-free, 300 psig (2 MPa max.)
Detected Compounds R-12, R-134a, R-22, hydrocarbons, air
Sensor Technology Non-Dispersive Infrared (NDIR)
Refrigerant Sample Size 0.3 ounces (8.5 grams) per sample
Refrigerant Loss during Purge Operation Typically 0.4 ounces (11 grams) per minute of
purge time. Refrigerant loss is dependent upon
many factors, such as refrigerant source size,
refrigerant source head space, initial refrigerant
contamination, and nal purge limit setting.
Power
Universal 110/220V AC, 50/60 Hz, 0.2 amps max.
Operational Temperature 39° F – 122° F (4° C – 50° C)
SAE1771: If the refrigerant being tested is identied as contaminated, any visual percentages
displayed of CFC-12 (R-12) or HFC-134a (R-134a) outside the design-certied value is informa-
tional and may not be accurate.
SAE CERTIFICATION NOTE: This equipment has not been design-certied for contaminate
detection of R-124 or R142B.