After analyzing the refrigerant, a PASS or FAIL LED ashes:
a. A ashing PASS LED indicates the refrigerant is 95%
pure or better.
b. A ashing FAIL LED indicates the refrigerant is less
than 95% pure.
c. The EXCESS AIR LED will light with either a PASS or
FAIL LED if the unit has detected a large amount of air
in the refrigerant.
Note: The indication of excess air may be the result of oil or
other contaminants trapped in the brass lter.
9. Disconnect the sample hose from the vehicle to prevent
refrigerant loss.
10. Press the NEXT button.
11. The CALIBRATING LED ashes:
a. Fully squeeze the rubber calibration bulb ve (5) times.
b. The unit may now be disconnected from the vehicle;
or press the NEXT button to begin another gas test.
Operating Instructions cont’d