INSTALLER SETUP MENU
15
Settings Display Adjustment Options Default
Compressor
Short Cycle
Delay
Cooling
Differential
Heating
Differential
The compressor short cycle
delay setting will not allow the
compressor to be turned on
for 5 minutes after it was last
turned off in order to protect
the compressor.
The cooling differential is factory
preset at 0.5°. This means that
whenever the room temperature
heats by 0.5° from the temperatur
e
setting, the cooling system will
turn on. If the cooling system
turns on
too often, increase the
temperature
differential.
The heating differential is factory
preset at 0.4°. This means that
whenever the room temperature
cools by 0.4° from the temperature
setting, the heating system will
turn on. If the heating system
turns on too often, increase the
temperature differential.
The compressor short
cycle delay setting can be
removed by selecting OFF.
ON
0.5
0.4
Prev step
Prev step
Prev step
Next step
Next step
Next step
The cooling differential
setting is adjustable from
0.2°F to 2°F.
The heating differential
setting is adjustable from
0.2°F to 2°F.