Install Instructions

INSTALLER SETUP MENU
14
Settings
Display Adjustment Options
Default
Filter
Change
Reminder
Room
Temperature
Calibration
Minimum
Compressor
On-Time
This setting will ash FILT in
the display after the elapsed
run time to remind the user to
change the lter. The OFF setting
will disable this feature.
This setting allows the installer
to change the calibration of the
room temperature display so
that, for example, the thermostat
would read 72°F instead of 70°F.
The installer can select the
minimum run time for the
compressor to help protect the
compressor from short-cycling.
The lter change reminder
can be adjusted from OFF
to 2000 hours in 50 hour
increments. Press the second
button from the top left side of
the thermostat to display the
current lter elapsed runtime.
The room temperature display
can be adjusted to read 3°
above or below the factory
calibrated temperature.
The minimum compressor run
time can be adjusted from OFF
to 3, 4, or 5 minutes. If 3, 4, or
5 is selected, the compressor
will run for at least the selected
time before turning off
(although the fan may continue
to run for a short time).
OFF
OFF
0
Next step
Prev step
Next step
Prev step
Next step
Prev step