Install Instructions
Settings Display Adjustment Options
Default
15
INSTALLER SETUP MENU
Compressor
Short Cycle
Delay
Cooling
Dierential
Heating
Dierential
The compressor short cycle
delay setting will not allow the
compressor to be turned on for 5
minutes after it was last turned off
in order to protect the compressor.
The cooling differential is factory
preset at 0.5°. This means that
whenever the room temperature
heats by 0.5° full degree from the
temperature setting, the cooling
system will turn on. If the cooling
system turns on too often, increase
the temperature differential.
The heating differential is factory
preset at 0.4°. This means that
whenever the room temperature
cools by 0.4° from the temperature
setting, the heating system will
turn on. If the heating system
turns on too often, increase the
temperature differential.
The compressor short
cycle delay setting
can be removed by
selecting OFF.
ON
0.5
0.4
Prev step
Prev step
Prev step
Next Step
Next step
Next step
The cooling differential
setting is adjustable
from 0.2°F to 2°F.
The heating differential
setting is adjustable
from 0.2°F to 2°F.