Specifications
SimpleComfort®
PRO
– Programmable
PRO
Series Programmable Thermostats
ICM Control Features and Applications Specifications Terminations
SC5010 PRO
• For single-stage heat/cool and single-stage heat
pump
• 7-day, 5-2-day and 5-1-1-day programming
• ICM patented Thermal Intrusion Barrier
• Manual or auto changeover
• ICM patent-pending SimpleSet™ Target
Programming technology
• Large display with backlight
• Permanent memory
• Dual powered (battery or hardwire)
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Easy access terminal block
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
RC, RH, C, W/O/B, Y,
G, S1, S2
SC5011 PRO
• For single-stage heat/cool or single-stage heat pump
• 7-day, 5-2-day and 5-1-1-day programming
• ICM patented Thermal Intrusion Barrier
• ICM SimpleSet
TM
Target Programming
• Large backlit LCD display
• Hardwired
• Auto or Manual changeover
• Permanent memory
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Easy access terminal block
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
RC, RH, C, W/O/B, Y,
G, S1, S2
SC5211 PRO
• For two-stage heat pump
• 7-day, 5-2-day and 5-1-1-day programming
• ICM patented Thermal Intrusion Barrier
• ICM SimpleSet
TM
Target Programming
• Large backlit LCD display
• Hardwired
• Auto or Manual changeover
• Permanent memory
• Adjustable temperature differential for each stage
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Easy access terminal block
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, Y1, Y2, W2, O/B,
G, E, L, S1, S2
SC5811 PRO
• For two-stage heat/cool or two-stage heat pump
• 7-day, 5-2-day and 5-1-1-day programming
• ICM patented Thermal Intrusion Barrier
• ICM SimpleSet
TM
Target Programming
• Large backlit LCD display
• Hardwired
• Auto or Manual changeover
• Permanent memory
• Adjustable temperature differential for each stage
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Easy access terminal block
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, W1/O/B, Y1, W2,
Y2, G, S1, S2
SC5812 PRO
• For three-stage heat/two-stage cool or two-stage
heat pump
• 7-day, 5-2-day and 5-1-1-day programming
• ICM patented Thermal Intrusion Barrier
• ICM SimpleSet
TM
Target Programming
• Large backlit LCD display
• Hardwired
• Dual fuel compatible
(requires ACC-OD103 outdoor sensor)
• Auto or Manual changeover
• Permanent memory
• Adjustable temperature differential for each stage
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Easy access terminal block
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, W1/O/B, Y1, W2,
Y2, G, W3, S1, S2
SC5813 PRO
• For three-stage heat/two-stage cool or two-stage
heat pump
• 7-day, 5-2-day and 5-1-1-day programming
• ICM patented Thermal Intrusion Barrier
• ICM SimpleSet
TM
Target Programming
• Large backlit LCD display
• Hardwired
• Auto or Manual changeover
• Permanent memory
• Adjustable temperature differential for each stage
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Easy access terminal block
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, W1/O/B, Y1, W2,
Y2, G, W3, S1, S2
315.233.5266
Phone
All features and specifications subject to change without notice.
Customer Service Fax
315.233.5282
Application Assistance
800.365.5525
Visit www.icmcontrols.com to find all
of our latest products, sell sheets and wiring diagrams
47