– Non-Programmable
PRO
Series Non-Programmable Thermostats
ICM Control Features and Applications Specifications Terminations
SC4010 PRO
• For single-stage heat/cool or single-stage heat pump
• ICM patented Thermal Intrusion Barrier
• ICM SimpleSet
TM
Target Programming
(configuration mode only)
• Large display with backlight
• Dual powered (battery or hardwired)
• Auto or Manual changeover
• Permanent memory
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Easy access terminal block
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
RC, RH, C, W/O/B, Y,
G, S1, S2
SC4011 PRO
• For single-stage heat/cool or single-stage heat pump
• ICM patented Thermal Intrusion Barrier
• ICM SimpleSet
TM
Target Programming
(configuration mode only)
• Large backlit LCD display
• Hardwired
• Auto or Manual changeover
• Permanent memory
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Easy access terminal block
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
RC, RH, C, W/O/B, Y,
G, S1, S2
SC4211 PRO
• For two-stage heat pump
• ICM patented Thermal Intrusion Barrier
• ICM SimpleSet
TM
Target Programming
(configuration mode only)
• Large backlit LCD display
• Hardwired
• Auto or Manual changeover
• Permanent memory
• Adjustable temperature differential for each stage
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Easy access terminal block
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, Y1, Y2, W2, O/B,
G, E, L, S1, S2
SC4811 PRO
• For two-stage heat/cool or two-stage heat pump
• ICM patented Thermal Intrusion Barrier
• ICM SimpleSet
TM
Target Programming
(configuration mode only)
• Large backlit LCD display
• Hardwired
• Auto or Manual changeover
• Permanent memory
• Adjustable temperature differential for each stage
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Easy access terminal block
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, W1/O/B Y1, W2,
Y2, G, S1, S2
SC4812 PRO
• For three-stage heat/two-stage cool or two-stage
heat pump
• ICM patented Thermal Intrusion Barrier
• ICM SimpleSet
TM
Target Programming
(configuration mode only)
• Large backlit LCD display
• Hardwired
• Dual fuel compatible (requires ACC-OD103 outdoor
sensor)
• Auto or Manual changeover
• Permanent memory
• Adjustable temperature differential for each stage
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Easy access terminal block
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, W1/O/B, Y1, W2,
Y2, G, W3, S1, S2
SC4813 PRO
• For three-stage heat/two-stage cool or two-stage
heat pump
• ICM patented Thermal Intrusion Barrier
• ICM SimpleSet
TM
Target Programming
(configuration mode only)
• Large backlit LCD display
• Hardwired
• Auto or Manual changeover
• Permanent memory
• Adjustable temperature differential for each stage
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Easy access terminal block
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, W1/O/B, Y1, W2,
Y2, G, W3, S1, S2
315.233.5266
Phone
All features and specifications subject to change without notice.
Customer Service Fax
315.233.5282
Application Assistance
800.365.5525
Visit www.icmcontrols.com to find all
of our latest products, sell sheets and wiring diagrams
46