Specifications

SimpleComfort® Standard Thermostats
Standard Programmable Thermostats
ICM Control Features and Applications Specifications Terminations
SC3000L
For single-stage heat/cool or single-stage heat pump
7-day, 5-2-day and 5-1-1-day programming
ICM patented Thermal Intrusion Barrier
New SimpleSet™ Target Programming technology
Large display with backlight
Adjustable temperature differential
Battery powered
Manual changeover
Permanent memory
Easy access terminal block
Field adjustable calibration
Millivolt compatible
Freeze protection
Zoning system compatible
Soft-touch controls
Selectable °F and °C
Electrical Rating:
24 VAC (18-30 VAC)
1 amp maximum per terminal
3 amp maximum total load
Easy access terminal block
Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
RC, RH, W, Y, O, B, G
SC3001L
For single-stage heat/cool or single-stage heat pump
7-day, 5-2-day and 5-1-1-day programming
ICM patented Thermal Intrusion Barrier
New SimpleSet™ Target Programming technology
Large display with backlight
Adjustable temperature differential
Hardwired
Manual changeover
Permanent memory
Easy access terminal block
Field adjustable calibration
Zoning system compatible
Soft-touch controls
Selectable °F and °C
Electrical Rating:
24 VAC (18-30 VAC)
1 amp maximum per terminal
3 amp maximum total load
Easy access terminal block
Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
RC, RH, W, Y, C, O,
B, G
SC3010L
For single-stage heat/cool or single-stage heat pump
7-day, 5-2-day and 5-1-1-day programming
ICM patented Thermal Intrusion Barrier
New SimpleSet™ Target Programming technology
Large display with backlight
Adjustable temperature differential
Dual powered
Manual changeover
Permanent memory
Easy access terminal block
Field adjustable calibration
4- or 5-wire compatible
Freeze protection
Zoning system compatible
Soft-touch controls
Selectable °F and °C
Electrical Rating:
24 VAC (18-30 VAC)
1 amp maximum per terminal
3 amp maximum total load
Easy access terminal block
Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
RC, RH, C, W, Y, O,
B, G
SC3211L
For two-stage heat pump
7-day, 5-2-day and 5-1-1-day programming
ICM patented Thermal Intrusion Barrier
New SimpleSet™ Target Programming technology
Large display with backlight
Adjustable temperature differential
Hardwired
Manual changeover
Permanent memory
Easy access terminal block
Field adjustable calibration
Vacation hold
Selectable °F or °C
Keypad lockout
Zoning system compatible
Soft-touch controls
Status LEDs
Selectable °F and °C
Electrical Rating:
24 VAC (18-30 VAC)
1 amp maximum per terminal
3 amp maximum total load
Easy access terminal block
Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, Y1, Y2, W2, O,
B, G, E, L
315.233.5266
Phone
All features and specifications subject to change without notice.
Customer Service Fax
315.233.5282
Application Assistance
800.365.5525
Visit www.icmcontrols.com to find all
of our latest products, sell sheets and wiring diagrams
44