Standard Non–Programmable Thermostats
ICM Control Features and Applications Specifications Terminations
SC2010L
• For single-stage heat/cool or single-stage heat pump
• ICM patented Thermal Intrusion Barrier
• SimpleSet™ target programming technology
(configuration only)
• Large display with backlight
• Adjustable temperature differential
• Dual powered
• Manual changeover
• Permanent memory
• Easy access terminal block
• Field adjustable calibration
• 4- or 5-wire compatible
• Freeze protection
• Keypad lockout
• Selectable °F and °C
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 3 amp maximum total load
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
RC, RH, C, W, Y, O,
B, G
SC2201L
• For two-stage heat, one-stage cool heat pump only
• ICM patented Thermal Intrusion Barrier
• Large backlit LCD display
• Hardwired
• Manual changeover
• Status LEDs
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, Y1, W2, O, B,
G, E
SC2201VL
• For two-stage heat, one-stage cool heat pump only
• ICM patented Thermal Intrusion Barrier
• Large backlit LCD display
• Hardwired
• Manual changeover
• Status LEDs
• Vertical design for easy J-box installations
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, Y1, W2, O, B,
G, E
SC2211L
• For three-stage heat, two-stage cool heat pump
• ICM patented Thermal Intrusion Barrier
• SimpleSet™ target programming technology
(configuration only)
• Large display with backlight
• Adjustable temperature differential
• Hardwired
• Manual changeover
• Permanent memory
• Easy access terminal block
• Field adjustable calibration
• Zoning system compatible
• Selectable °F and °C
• Permanent memory
• Status LED
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, Y1, Y2, W2, O,
B, G, E, L, W3
SC2311L
• For two-stage heat, single-stage cool or single-stage
heat pump with auxiliary heat
• ICM patented Thermal Intrusion Barrier
• SimpleSet™ target programming technology
(configuration only)
• Large display with backlight
• Adjustable temperature differential
• Hardwired
• Manual changeover
• Permanent memory
• Easy access terminal block
• Field adjustable calibration
• Selectable °F and °C
• Status LED
• Electrical Rating:
• 24 VAC (18-30 VAC)
• 1 amp maximum per terminal
• 4 amp maximum total load
• Temperature control ranges: 45°F to 90°F,
Accuracy ± 1°F
R, C, W1/O/B, Y, W2,
E, G