Specifications

Defrost Controls
Form, Fit and Functional OEM Replacement Parts (continued)
ICM Control Features and Applications Specifications Replaces
ICM316
Replacement for Trane 21C142827G01
Low cost, time and temperature defrost
Time and temperature terminate
Pin-selectable intervals: 50/70/90 minutes
Test pins reduce test time by 256x
High power output (1/2 HP fan @ 240 VAC)
Strip heat, reversing valve outputs (24 VAC, 1 amp)
Voltage: 18-30 VAC
Frequency: 50-60 Hz
Outdoor fan relay output:
• 1/2 HP fan @ 240 VAC
Strip heat, reversing valve outputs:
• 24 VAC, 1 amp
Defrost time: 10-minute fixed
Interval times: Pin-Sel. 50/70/90 min.
Trane:
21C142827G01
CNT1152
CNT1642
ICM317
Anti-bang reversing valve feature
Select 0 or 3 minute anti-short cycle time
Time and temperature terminate
10-minute fixed defrost time
Test pins reduce test time by 256x
HOLD input tracks compressor run times
Voltage: 18-30 VAC
Frequency: 50-60 Hz
Output:
Type: Relay, SPST
N.O.: 1 amp
Defrost time: 10-minute fixed
Interval times: Pin-selectabe
50/70/90 minutes
N/A
ICM318
Replacement for Goodman B1226008
Low cost, time and temperature defrost
Time and temperature terminate
Pin-selectable intervals: 30/60/80 minutes
Test pins reduce test time by 256x
HOLD input tracks compressor run times
High power output (1/2 HP fan @ 240 VAC)
Strip heat, reversing valve outputs (24 VAC, 1 amp)
Voltage: 18-30 VAC
Frequency: 50-60 Hz
Outdoor fan relay output:
• 1/2 HP fan @ 240 VAC
Strip heat, reversing valve outputs:
• 24 VAC, 1 amp
Defrost time: 10-minute fixed
Interval times: Pin-selectabe
30/60/80 minutes
Goodman:
B1226008
ICM: W1001-4
ICM319
Replacement for Nordyne: 624519A
Low cost, time and temperature defrost
Time and temperature terminate
10-minute fixed defrost time
Pin-selectable intervals: 30/60/90 minutes
Test pins reduce test time by 256x
Recycle function melts frost on coils
Integral short cycle protection
Voltage: 18-30 VAC
Frequency: 50-60 Hz
Outdoor fan relay output:
• 1/2 HP fan @ 240 VAC
Strip heat, reversing valve outputs:
• 24 VAC, 1 amp
Anti-short cycle time: 5 minutes
Defrost time: 10-minute fixed
Interval times: Pin-selectabe
30/60/90 minutes
ICM: DFORB24A2I300
Nordyne: 624519A
ICM320
Replacement for Carrier HK32FA006
Low cost, time and temperature defrost
Time and temperature terminate
10-minute fixed defrost time
Pin-selectable intervals: 30/50/90 minutes
Test pins reduce test time by 256x
Stable pin post construction
Voltage: 18-30 VAC
Frequency: 50-60 Hz
Outdoor fan relay output:
• 1/2 HP fan @ 240 VAC
N.O.: 2 amps
Form: SPST
Defrost time: 10-minute fixed
Interval times: Pin-selectabe
30/50/90 minutes
Carrier:
HK25SZ359/9A
HK32FA006
ICM321
Low cost, time and temperature defrost
Time and temperature terminate
10-minute fixed defrost time
Pin-selectable intervals: 30/50/90 minutes
Test pins reduce test time by 256x
High power output, outdoor fan (1/2 HP fan @ 240 VAC)
Strip heat, reversing valve outputs (24 VAC, 1 amp)
Integral short cycle protection
Voltage: 18-30 VAC
Frequency: 50-60 Hz
Outdoor fan relay output:
N.O.: 20 amps
N.C.: 10 amps
Form: SPDT
Anti-short cycle time: 5 minutes
Defrost time: 10-minute fixed
Interval times: Pin-selectabe
30/50/90 minutes
Carrier:
CES0110063-00
CES0110063-01
CES0110063-02
CES0110063-02A
CES0130024-01
150-83-6A
ICM322
Low cost, time and temperature defrost
Time and temperature terminate
10-minute fixed defrost time
Pin-selectable intervals: 30/50/90 minutes
Test pins reduce test time by 256x
High power output, outdoor fan (1/2 HP fan @ 240 VAC)
Strip heat, reversing valve outputs (24 VAC, 1 amp)
Voltage: 18-30 VAC
Frequency: 50-60 Hz
Outdoor fan relay output:
N.O.: 20 amps
N.C.: 10 amps
Defrost time: 10-minute fixed
Interval times: Pin-selectabe
30/50/90 minutes
Carrier:
CES0130024-00
ICM323
Same as ICM304 but for heat active reversing valve
Sensor input for defrost terminate
Time and temperature terminate
10-minute fixed defrost time
Pin-selectable intervals: 30/60/90 minutes
Y input tracks compressor run times
Integral short cycle protection
Heat active reversing valve
Voltage: 18-30 VAC
Frequency: 50-60 Hz
Strip heat, reversing valve outputs:
• 24 VAC, 1 amp
Defrost time: 10-minute fixed
Interval times: Pin-selectabe
30/60/90 minutes
ICP:
Heat active (B) RV
315.233.5266
Phone
All features and specifications subject to change without notice.
Customer Service Fax
315.233.5282
Application Assistance
800.365.5525
Visit www.icmcontrols.com to find all
of our latest products, sell sheets and wiring diagrams
32