Specifications
Defrost Controls
Form, Fit and Functional OEM Replacement Parts (continued)
ICM Control Features and Applications Specifications Replaces
ICM316
• Replacement for Trane 21C142827G01
• Low cost, time and temperature defrost
• Time and temperature terminate
• Pin-selectable intervals: 50/70/90 minutes
• Test pins reduce test time by 256x
• High power output (1/2 HP fan @ 240 VAC)
• Strip heat, reversing valve outputs (24 VAC, 1 amp)
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Outdoor fan relay output:
• 1/2 HP fan @ 240 VAC
• Strip heat, reversing valve outputs:
• 24 VAC, 1 amp
• Defrost time: 10-minute fixed
• Interval times: Pin-Sel. 50/70/90 min.
•
Trane:
21C142827G01
CNT1152
CNT1642
ICM317
• Anti-bang reversing valve feature
• Select 0 or 3 minute anti-short cycle time
• Time and temperature terminate
• 10-minute fixed defrost time
• Test pins reduce test time by 256x
• HOLD input tracks compressor run times
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Output:
• Type: Relay, SPST
• N.O.: 1 amp
• Defrost time: 10-minute fixed
• Interval times: Pin-selectabe
50/70/90 minutes
N/A
ICM318
• Replacement for Goodman B1226008
• Low cost, time and temperature defrost
• Time and temperature terminate
• Pin-selectable intervals: 30/60/80 minutes
• Test pins reduce test time by 256x
• HOLD input tracks compressor run times
• High power output (1/2 HP fan @ 240 VAC)
• Strip heat, reversing valve outputs (24 VAC, 1 amp)
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Outdoor fan relay output:
• 1/2 HP fan @ 240 VAC
• Strip heat, reversing valve outputs:
• 24 VAC, 1 amp
• Defrost time: 10-minute fixed
• Interval times: Pin-selectabe
30/60/80 minutes
•
Goodman:
B1226008
• ICM: W1001-4
ICM319
• Replacement for Nordyne: 624519A
• Low cost, time and temperature defrost
• Time and temperature terminate
• 10-minute fixed defrost time
• Pin-selectable intervals: 30/60/90 minutes
• Test pins reduce test time by 256x
• Recycle function melts frost on coils
• Integral short cycle protection
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Outdoor fan relay output:
• 1/2 HP fan @ 240 VAC
• Strip heat, reversing valve outputs:
• 24 VAC, 1 amp
• Anti-short cycle time: 5 minutes
• Defrost time: 10-minute fixed
• Interval times: Pin-selectabe
30/60/90 minutes
• ICM: DFORB24A2I300
• Nordyne: 624519A
ICM320
• Replacement for Carrier HK32FA006
• Low cost, time and temperature defrost
• Time and temperature terminate
• 10-minute fixed defrost time
• Pin-selectable intervals: 30/50/90 minutes
• Test pins reduce test time by 256x
• Stable pin post construction
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Outdoor fan relay output:
• 1/2 HP fan @ 240 VAC
• N.O.: 2 amps
• Form: SPST
• Defrost time: 10-minute fixed
• Interval times: Pin-selectabe
30/50/90 minutes
•
Carrier:
HK25SZ359/9A
HK32FA006
ICM321
• Low cost, time and temperature defrost
• Time and temperature terminate
• 10-minute fixed defrost time
• Pin-selectable intervals: 30/50/90 minutes
• Test pins reduce test time by 256x
• High power output, outdoor fan (1/2 HP fan @ 240 VAC)
• Strip heat, reversing valve outputs (24 VAC, 1 amp)
• Integral short cycle protection
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Outdoor fan relay output:
• N.O.: 20 amps
• N.C.: 10 amps
• Form: SPDT
• Anti-short cycle time: 5 minutes
• Defrost time: 10-minute fixed
• Interval times: Pin-selectabe
30/50/90 minutes
•
Carrier:
CES0110063-00
CES0110063-01
CES0110063-02
CES0110063-02A
CES0130024-01
150-83-6A
ICM322
• Low cost, time and temperature defrost
• Time and temperature terminate
• 10-minute fixed defrost time
• Pin-selectable intervals: 30/50/90 minutes
• Test pins reduce test time by 256x
• High power output, outdoor fan (1/2 HP fan @ 240 VAC)
• Strip heat, reversing valve outputs (24 VAC, 1 amp)
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Outdoor fan relay output:
• N.O.: 20 amps
• N.C.: 10 amps
• Defrost time: 10-minute fixed
• Interval times: Pin-selectabe
30/50/90 minutes
•
Carrier:
CES0130024-00
ICM323
• Same as ICM304 but for heat active reversing valve
• Sensor input for defrost terminate
• Time and temperature terminate
• 10-minute fixed defrost time
• Pin-selectable intervals: 30/60/90 minutes
• Y input tracks compressor run times
• Integral short cycle protection
• Heat active reversing valve
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Strip heat, reversing valve outputs:
• 24 VAC, 1 amp
• Defrost time: 10-minute fixed
• Interval times: Pin-selectabe
30/60/90 minutes
•
ICP:
Heat active (B) RV
315.233.5266
Phone
All features and specifications subject to change without notice.
Customer Service Fax
315.233.5282
Application Assistance
800.365.5525
Visit www.icmcontrols.com to find all
of our latest products, sell sheets and wiring diagrams
32