Specifications
Defrost Controls
Form, Fit and Functional OEM Replacement Parts
ICM Control Features and Applications Specifications Replaces
ICM300
• Replacement for OEM Type 621
• Low cost, time and temperature defrost
• HOLD input tracks compressor run times
• Time and temperature terminate
• 10-minute fixed defrost time
• Pin-selectable intervals: 30/60/90 minutes
• Test pins reduce test time by 256x
• Stable pin post construction
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Output:
• Relay, SPST
• N.O.: 1 amp
• Defrost time: 10-minute fixed
• Interval times: Pin-Sel. 30/60/90 min.
• Amana: C64301-1, C64310-1
• Arcoaire: 32312-00, 3232140
• Artesian: 10321-00
• Coleman: 3030A374
• Essex: 621-1 to 621-11,
621-310
• Goodman: B12260-06
• Heil Quaker: HQ1052757
• Honeywell: ST74A1004,
ST74A1020, ST74A1038
• ICP: 1052757
• Intertherm: 6208800
• Lennox: 33G9501
• Rheem: 47-21776-01
• Robertshaw/Uni-Line: TD-
10, DT2-1000
• Snyder General: 1395-329
• Steveco: 90-621
• Therm-O-Disc: 26E-10
• Weatherking (Addison):
840-4-5548
• White-Rodgers: 90-621
ICM301
• Low cost, time and temperature defrost
• Sensor input for defrost terminate
• Time and temperature terminate
• 10-minute fixed defrost time
• Pin-selectable intervals: 30/60/90 minutes
• Test pins reduce test time by 256x
• HOLD input accumulates actual compressor run times
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Output:
• Type: Relay, SPST
• N.O.: 1 amp
• Defrost time: 10-minute fixed
• Interval times: Pin-Sel. 30/60/90 min.
• Goettl: 305007
• ICM: DFOSP24A2
• Rheem: 47-21776-06
ICM302
• Low cost, time and temperature defrost
• Time and temperature terminate
• 10-minute fixed defrost time
• Pin-selectable intervals: 30/60/90 minutes
• Test pins reduce test time by 256x
• Strip heat, reversing valve outputs
• High power output (1 HP fan @ 240 VAC)
• Integral short cycle protection
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Output:
• Type: Relay, SPST
• N.O.: 1 amp
• Anti-short cycle time: 5 minutes
• Defrost time: 10-minute fixed
• Interval times: Pin-Sel. 30/60/90 min.
• ICM: DFORB-AB1004
• Nordyne:
621301A
621579B
621579C
917178
ICM303
• Replacement for York 03101251000
• Time and temperature terminate
• Integral short cycle protection
• Pin-selectable intervals: 30/60/90 minutes
• High/low pressure switch monitoring
• High power, condenser relay output
• Strip heat, reversing valve outputs
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Relay output: 1 HP fan @ 240 VAC
• Strip heat, reversing valve outputs:
• 24 VAC, 2 amps
• Defrost time: 10-minute fixed
• Interval times: Pin-Sel. 30/60/90 min.
• Evcon: 9218-374
• ICM: DFORF
• York:
03101251000
9218-3741
ICM304
• Replacement for ICP 1069364
• Sensor input for defrost terminate
• Time and temperature terminate
• 10-minute fixed defrost time
• Pin-selectable intervals: 30/60/90 minutes
• Y input tracks compressor run times
• Integral short cycle protection
• Cool active reversing valve
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Strip heat, reversing valve outputs:
• 24 VAC, 1 amp
• Defrost time: 10-minute fixed
• Interval times: Pin-Sel. 30/60/90 min.
• ICP: 1069364
ICM307
• 3-minute anti-short cycle protection
• Low cost, time and temperature defrost
• Time and temperature terminate
• 10-minute fixed defrost time
• HOLD input tracks compressor run times
• Pin-selectable intervals: 30/60/90 minutes
• Test pins reduce test time by 256x
• Voltage: 18-30 VAC
• Frequency: 50-60 Hz
• Output:
• Type: Relay, SPST
• N.O.: 1 amp
• Anti-short cycle time: 3 minutes
• Defrost time: 10-minute fixed
• Interval times: Pin-Sel. 30/60/90 min.
• Fast: 1093410
• Lennox: 86G16
• Ranco: DT2
ICM315
• Solid state replacement for Ranco E-15
• Reliable thermistor-type sensor is less susceptible to breakage,
easier to mount
• Replaces faulty bulb-type sensors
• 10-minute fixed defrost time
• Pin-Sel. interval times (30/45/90)
• Test pins reduce test time by 256x
• Stable pin post construction
• Time and temperature terminate
• Voltage: 24, 120, 240 VAC
• Frequency: 50-60 Hz
• Output:
• Type: Relay, SPDT
• N.O.: 20 amps
• N.C.: 10 amps
• Defrost time: 10-minute fixed
• Interval times: Pin-Sel. 30/45/90 min.
•
Avion:
DFT100
• Ranco: E-15
315.233.5266
Phone
All features and specifications subject to change without notice.
Customer Service Fax
315.233.5282
Application Assistance
800.365.5525
Visit www.icmcontrols.com to find all
of our latest products, sell sheets and wiring diagrams
31