Specifications

Gas Ignition Controls
ICM293
Intermittent Pilot Gas Ignition Control Module
For use with intermittent pilot boilers, furnaces
and other heating appliances
Microprocessor-based
Monitors timing, trial for ignition, flame sensing
and lockout
Remote flame sensing
100% lockout safety feature
Compatible with LP or Natural Gas
Status LED for fault codes to aid in
troubleshooting
• Control Voltage: Line 24 VAC (18-30 VAC) 50/60 Hz
• Anticipator Setting: 0.2A plus valve load @ 24 VAC
• Prepurge: 15 seconds
Trial for Ignition: 85 seconds
• Lockout: 60 minutes
• Flame Failure Response Time: 0.5 seconds
• Status LED: See product label for error codes
• Operating Temperature:
– Min. ambient temperature rating is -40°F (-40°C)
– Max. ambient rating when used with 2.0A main valve
is 165°F (74°C)
• Relative Humidity: 0% to 95% non-condensing
Lennox:
30W33 ignition control
Robertshaw:
735L (18G91) or 745
(95H04) ignition controls
Johnson Controls:
G776 (63K2401, 41K8701,
69J3601) ignition controls
ICM294
Intermittent Pilot Gas Ignition Control Module
For use with intermittent pilot boilers, furnaces
and other heating appliances
Microprocessor-based
Monitors timing, trial for ignition, rollout switch
flame sensing and lockout
Remote flame sensing
100% lockout safety feature
Compatible with LP or Natural Gas
Control Voltage: Line 24 VAC (18-30 VAC) 50/60 Hz
Anticipator Setting: 0.2A plus valve load @ 24 VAC
Prepurge: None
Trial for Ignition: 85 seconds
Flame Failure Response Time: 0.5 seconds
Retry: None
Operating Temperature:
Min. ambient temperature rating is -40°F (-40°C)
Max. ambient rating when used with 2.0A main valve
is 160°F (71°C)
Relative Humidity: 0% to 95% non-condensing
Johnson Controls:
G770RJA-1
York: 025-27762-700 and
comparable ignition controls
ICM295
Spark Ignition Control Module
Microprocessor based
For use with intermittent pilot boilers, furnaces
and other heating appliances
Continuous spark until pilot flame established
Push-on, high tension quick connect terminals
Compatible with LP or Natural Gas
Control Voltage: Line 24 VAC (18-30 VAC) @ 50/60Hz
Prepurge: 0 or 10 seconds (system dependent)
Retries: Continuous
Operating Temperature: -40°F to 176°F
-40°C to 75°C
Relative Humidity: 0% to 95% non-condensing
Spark Frequency: 15Hz for 90 seconds, 10Hz
thereafter
Carrier: LH33WZ510
ICM296
Spark Ignition Control Module
Microprocessor based
For use with intermittent pilot boilers, furnaces
and other heating appliances
100% safety lockout
Compatible with LP or Natural Gas
Control Voltage: Line 24 VAC (18-30 VAC) @ 50/60Hz
Prepurge: None
Lockout: 5-6 minutes
Retries: None
Operating Temperature: -40°F to 176°F
-40°C to 75°C
Relative Humidity: 0% to 95% non-condensing
Relay Contact Rating: 1 amp @ 24 VAC
Trail for Ignition: 90 seconds
Flame Failure Response Time: 0.8 sec. max.
Spark Frequency: 60 Hz
Carrier: LH33WZ512A
ICM2901
For use with intermittent pilot boilers, furnaces
and other heating appliances
Microprocessor-based precision
Monitors timing, trial for ignition, rollout switch,
flame sensing and lockout
Remote flame sensing
100% lockout safety feature
Compatible with LP or Natural Gas
Control Voltage: Line 24 VAC (18-30 VAC) 50/60 Hz
Anticipator Setting: 0.3A plus valve load @ 24 VAC
Prepurge: None
Trial for Ignition: 85 seconds
Flame Failure Response Time: 0.5 seconds
Retry: None
Operating Temperature:
Min. ambient temperature rating is -40°F (-40°C)
Max. ambient rating when used with 2.0A main valve
is 160°F (71°C)
Relative Humidity: 0% to 95% non-condensing
ICM: 294
Johnson Controls:
G770RJA-1
York: 025-27762-700
and comparable ignition
controls.
ICM2902
For use with intermittent pilot boilers, furnaces
and other heating appliances
Microprocessor-based precision
Monitors timing, trial for ignition, flame sensing
and lockout
Remote flame sensing
100% lockout safety feature
Compatible with LP or Natural Gas
Status LED for fault codes to aid in
troubleshooting
Control Voltage: Line 24 VAC (18-30 VAC) 50/60 Hz
Anticipator Setting: 0.3A plus valve load @ 24 VAC
Prepurge: 15 seconds
Trial for Ignition: 60 minutes
Lockout: 2 seconds
Flame Failure Response Time: 0.5 seconds
Status LED: See product label for error codes
Operating Temperature:
Min. ambient temperature rating is -40°F (-40°C)
Max. ambient rating when used with 2.0A main valve
is 160°F (71°C)
Relative Humidity: 0% to 95% non-condensing
ICM: 293
Johnson Controls:
G776
(63K2401, 41K8701,
69J3601) ignition controls
Lennox: 30W33 ignition
control,
Robertshaw: 735L
(18G91) or 745 (95H04)
ignition controls
315.233.5266
Phone
All features and specifications subject to change without notice.
Customer Service Fax
315.233.5282
Application Assistance
800.365.5525
Visit www.icmcontrols.com to find all
of our latest products, sell sheets and wiring diagrams
29