Specifications

Furnace Controls
Furnace Control Modules
ICM Control Features and Applications Specifications Replaces
ICM289
Controls inducer fan motor, blower fan and monitors
limit switches
Microprocessor based design
Functions with all 24 VAC thermostats
Voltage Range: Line (98-132 VAC) @ 60 Hz
Cool blower: 20A @ 120 VAC
Heat blower: 20A @ 120 VAC
Inducer motor: 5A @ 120 VAC
Cool blower On Delay: 1 second
Cool blower Off Delay: 1 second
Heat blower On Delay: 45 seconds
Heat blower Off Delay: 90, 150, 210, 270 sec.
Lennox:
Replaces all BCC1,
BCC2 and BCC3 circuit
boards, including 48K98
and 45K48.
ICM291
Direct Spark Ignition (DSI) control board
Microprocessor-based
Controls combustion, blower and indoor motors; spark
ignitor and the gas valve
Monitors timing, trial for ignition, flame sensing and
lockout
100% lockout safety feature
Compatible with LP or Natural Gas
Status LED for fault codes to aid in troubleshooting
Control voltage: 24 VAC (18-30 VAC), 60 Hz
Line voltage: 208/230 VAC, 60 Hz
Power cons: 0.3A plus gas valve current @ 24 VAC
Operating temp: -40°C (-40°F) to 75°C (176°F)
Timing
Pre-purge: 45 seconds
Trial for Ignition: 5+2 seconds
Retry period: Every 20 seconds for 15 minutes
Lockout: manual reset
Post-purge: 45 seconds
Inputs
Power: RT and C
Thermostat interface: R, W and G
Safety switches: RS, LS, and CS
Combustion motor Hall Effect sensor
Flame sensing
Outputs
Spark
Gas Valve: GV
Combustion motor: CM
Blower motor: BM
Indoor fan motor: IFO
LED indicators
Red LED: Steady ON- normal operation
Flashing – fault codes
Carrier:
LH33WP003/3A
ICM292
Direct Spark Ignition (DSI) control board
Microprocessor-based
Controls Induced Draft and indoor blower motors;
humidifier output, spark ignitor and gas valve
Monitors timing, trial for ignition, flame sensing and
lockout
100% lockout safety feature
Compatible with LP or Natural Gas
Status LEDs for fault codes to aid in troubleshooting
Control voltage: 24 VAC (18-30 VAC), 60 Hz
Line voltage: 115 VAC, 60 Hz
Power cons: 0.3A plus gas valve current at 24 VAC
Operating temp: -40°C (-40°F) to 75°C (176°F)
Timing
Pre-purge: 30 seconds
Trial for ignition: 7 seconds
Retries: 2 groups of 2, 30 seconds delay within the
group and 3 minutes delay between groups
Lockout: 1 hour
Post-purge: 90, 120, 160 and 180 seconds
Inputs
Power: 24 VAC and COM
Thermostat interface: R, W, Y and G
System switches: Vent Pressure and Limit switches
(Main and Over-temperature switches in series)
Flame Sensing
Heat blower OFF delay: SW1 toggle switch
Outputs
Spark: SE
Gas Valve: GV
Inducer draft motor: IDM
Electric Air Cleaner: EAC
Humidifier relay: HUM
Heat/Cool relay: H/C
Blower motor: FAN, COOL and HEAT speeds
LED indicators
Power, green LED: PWR
Status, green LED: OK
Flame status, yellow LED: FLAME
Rheem: 62-24140-04
ICM2801
Controls vent motor, blower control, hot surface ignitor
and gas valve
Monitors timing, trial for ignition, flame sensing and
lockout
Microprocessor-based
Reverse polarity protection
100% lockout safety feature
Compatible with LP or Natural Gas
Twinning compatible with another ICM2801 control
Status LED for fault codes to aid in troubleshooting
Line voltage: 98-132 VAC @ 60 Hz
Ignitor: 5A, 120 VAC
Cool blower: 10A, 2 HP, 240 VAC
Heat: 5A, ½ HP, 250 VAC
Inducer blower: 4A, 120 VAC
Gas valve: 1A, 24 VAC
York/Evcon:
7990-319P
315.233.5266
Phone
All features and specifications subject to change without notice.
Customer Service Fax
315.233.5282
Application Assistance
800.365.5525
Visit www.icmcontrols.com to find all
of our latest products, sell sheets and wiring diagrams
27